Accessory Connector (16 Channel Models Only)
Customizing the Expanded Accessory Connector
6
Phone Patch
RSS LOCATION
DEFINITION
The phone patch interface package was designed for the i50x phone patch, but
can be used with a variety of Motorola and third party phone patches.
DEFAULT/CHOICES
Refer to Table 10-23 on page 10-14 in Appendix H for defaults.
DEPENDENCIES
The Internal Accessory MUST be set to NONE.
IMPORTANT NOTE
Incompatible with DTMF Decoder Board.
RECOMMENDATIONS
To avoid any transients that may occur while turning on the radio, we suggest
that the power-up delay be at least 500ms.
SEE ALSO
External Accessories, Internal Accessories, DTMF Decoder Board
PROGRAMMING PROCEDURE
1. Press F4 at the
MAIN MENU
to get to the
CHANGE/VIEW CODEPLUG MENU.
4. Use the
↑ ↓
arrow keys to select Phone Patch.
If the choice does not appear, check that the
Internal Accessory is set to NONE.
2. At the
CHANGE/VIEW CODEPLUG MENU
,
press
F2
to get to the
RADIO-WIDE
screen.
5. To customize the accessory package, press
F9
to
get to the
ACCESSORY CONNECTOR CON-
FIGURATION
screen and make the desired
changes.
3. Press
Tab
or
Enter/Return
until the Acc. Exter-
nal field is highlighted.
MAIN
MENU
➠
F4
➠
F2
CHANGE/
VIEW
➠
Tab
RADIO
WIDE
Acc. External
field