![Radius Design WALL FLAME Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/radius-design/wall-flame/wall-flame_manual_780607006.webp)
14.04.2011
6
ENGLISH
remove all packaging materials.
5
remove all inflammable elements from the
chamber.
6
place the ceramic sponge into the combusti-
on chamber, and place the chamber inside
the safety bowl.
7
place the extinguisher sliding gauges on the
combustion chamber. the extinguisher slide
without the holes should be facing away from
you.
8
make sure that no foils, packaging or other
combustible materials are in the combusti-
on chamber. remove the extinguisher slide
and fill the combustion chamber with max.
1.7 l bioethanol (max. marking). make sure
that no fuel is spilt next to the combustion
chamber. the ceramic sponge must not be co-
vered with ethanol. only use radius design
fuel (artic.-nr. 536 3l / 536 5l or 536 10l), do
not throw any combustible items or liquids
into the combustion chamber. the burning
time of combustion chambers replenished up
to the maximum limit is approx. 3.4 hours.
when the tank level is low wait 10 minutes
after filling before lighting to allow the ce-
ramic sponge to absorb ethanol. never put
fuel into the sponge when it is hot or duri-
ng operation. before it is put into operation
again the burner must have cooled down.
allow at least one hour for this.
combustion
chambers must not be replenished while
burning.
before recommisioning, the combu-
stion chamber needs to be refilled until the
max. marking is reached.
11
12
insert the panels carefully into the specially
provided slits. remove one on the small pa-
nels before filling the combustion chamber.
9
the fireplace comes with a spout that fits on
all RADIUS DESIGN bioethanol cans, and you
should keep it.
10
select a suitable place for the assembly. drill
3 holes (7 mm diameter). use dowels to at-
tach the fixing panel safely and firmly to the
wall. important: allow a distance of at least
2 meters to combustible objects. there must
be a minimum distance of 1.80 meter to the
ceiling. align the fixing panel and mark the
drilling holes. after drilling the holes affix
the wall mounting panel. check whether you
need special dowels for mouting the panel on
the wall.
1
3
hang HOME FLAME on the mounting track and
check that it is firmly secured.
Hang the anti-derailing device on the wallfla-
me frame as shown.
2
After hanging, mark the fixing hole. Hang
out the wallflame once more, drill a hole on
the marked location, re-mount the wallflame
once more with the anti-derailing device,
screwing this in tightly. Check that the HOME
FLAME holds securely.
4