![RadiSys C1XTN02 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/radisys/c1xtn02/c1xtn02_service-manual_780527039.webp)
EPC-3221 CompactPCI
®
System Controller Board and C1XTN02 Transition I/O Module
28
Service Manual
Specifications
Overview
Listed in the tables below are system specifications and environmental tolerances for the
EPC-3221 SCB.
Note:
These specifications are subject to change without notice.
Environmental
Environmental tolerances are listed in the following table:
Cooling
Airflow requirements for the SCB are listed in the following table:
Note:
The following table lists the minimum unimpeded airflow in linear feet per minute (LFM)
required across the processor for operations at the specified ambient temperature at sea level.
A Note on Thermal Specifications
RadiSys validates the operating specifications of its products by testing with the “hottest”
available hardware and software configuration to maximize the power supply draw and
generate a worst-case scenario. Despite these efforts, the specifications outlined above are
only benchmarks and should be regarded as such.
Operating
Non-Operating
Temperature
0 to 57 °C (32 to 134.6 °F)
at 200 LFM
†
-40 to 70 °C (-40 to 158 °F)
Humidity
5 – 95% @ 40 °C,
non-condensing
0 – 95% @ 40 °C,
non-condensing
Shock
1 G @ 10 ms
30 G @ 10 ms
Vibration
0.25 G @ 5 – 150 Hz
5 G @ 5 – 150 Hz
Altitude
15,000 ft. (4,572 m)
50,000 ft. (15,240 m)
†
See the cooling conditions outlined below for extended temperature specifications.
Airflow
600 LFM
400 LFM
200 LFM
100 LFM
0 LFM
Maximum
Ambient
69 °C
(156.2 °F)
66 °C
(150.8 °F)
57 °C
(134.6 °F)
44 °C
(111.2 °F)
Not
Recommended
Ambient temperature is measured at the leading edge of the CPU heatsink with a 433 MHz
processor installed and all components fully populated.