Fire Unlock. This state allows free access no matter what the previous door state
or armed state is. This is a programmable option that can be used to allow free
access into the building upon a fire alarm.
Automatic Functions and Door State. The D9210B has two automatic
functions that control door state based on the armed state of the area:
Auto Door. With this function as Yes, the door will be locked when the area is
armed and unlocked when the area is disarmed. Perimeter armed is considered
an armed state for this function.
Disarm on Open. With this function as Yes, a user with valid access rights will
activate the strike and disarm the system after the door is opened. With this
function as no, the area will disarm upon the strike activation.
Access Levels
Armed State rights Users can be prevented from access depending upon the
armed state of the area that the D9210B is assigned to. M-indicates the user has
access no matter what the armed state, P- indicates the user has access as long
as the Area is perimeter armed or disarmed and D-indicates the user only has
access when the area is completely disarmed.
Disarm Access Level. Users are allowed to disarm the area with an access id.
Care should be taken to ensure that the user first has the authority to activate the
strike based on the Armed State. P-indicates the user will disarm the area from
Master to Perimeter Instant. D- indicates the user will disarm the area from
Master or Perimeter to the disarmed state.
Skeds
Unlock Door . Provides an automatic free access at a specific time period.
Requires a Normal Door Sked to return the door to normal. Can be overridden by
manual control at the control center.
Secure Door. Provides an automatic prevention of access at a specific time
period. Requires a Normal Door Sked to return to normal. Can be overridden by
manual control at the control center.
Lock Door. Provides an automatic lock door state at a specific time to return the
door to normal requiring valid cards/tokens to allow access.
Message Suppression. Provides an automatic message off/on function at a
specific time for Door and Access Granted or No Entry messages.
Access Ctl Level On/Off. Provides an automatic on/off for each of the 14 levels
dealing with the access control. Once a level is turned off, all doors are affected.
Modular Design. The D9210B can be replaced by simply disconnecting the
existing unit and connecting a new one with the same dipswitch setting. The
panel will download stored data to the new unit when it is powered up and
connected to the SDI bus.
Diagnostics. Patterns of LED activation will indicate door state and ID validity.
Other indications include SDI failure. (see Table 5, LED Trouble Shooting
Guide).