42
is turned on when the thr gimbal is less than -90%.
a~x
Triggered when the parameter v1 is approximately equal to the
data v2, approximately equal to the range of about 10%
a>x
Triggered when parameter v1 is greater than data v2
a<x
Triggered when parameter v1 is less than data v2
|a|>x
Triggered when the absolute value of parameter v1 is greater than v2,
the absolute value is that it will become positive no matter whether it
is positive or negative
|a|<x
Triggered when the absolute value of parameter v1 is less than v2
AND
AND operation is triggered when both parameters v1 and v2 meet
the conditions. For example, v1 is the switch SA ↑ and v2 is SB ↑ ,
which indicates that the current logic switch can be turned on when
both SA and SB switches are in the ↑ position.
OR
OR operation, which can be triggered when one of the parameters v1
and v2 meets the conditions, or when all the conditions are met
XOR
Exclusive OR operation, triggered when one of the parameters v1 and
v2 meets the conditions, not triggered when all the conditions are
met or all the conditions are not met
Edge
Is a momentary switch (very short duration, about 30 ms), it will be
triggered when V1 meets the conditions
V1: Can be physical switch, logic switch, trim button
V2: It is divided into two parts [t1: t2], t1 is the minimum value, and
t2 is the maximum duration of V1. The logic switch is triggered only
after t1 when V1 meets the conditions, and is closed before t2.
If t2 is left as "---" then only t1 is applicable. When V1 changes from
on to off (ie falling edge), the logic switch will be triggered, and then
the logic switch will be turned on for 1 processing cycle (about 30
ms). If t2 is set to "<<", the logic switch (ie, rising edge) is triggered
when V1 changes from off to on.
a=b
Triggered when the parameter v1 is equal to the parameter v2. For
example, when the value of the thr gimbal and the value of the ail
Содержание TX12