3. Installation
8
Mains operated products should be installed by a
licensed electrician
as per the requirements of AS3000.
Failure to install this unit correctly may expose the user to shock or fire
hazards.
This unit is not waterproof and must not be exposed to dripping or
splashing liquids.
Mixing the Live and Neutral connections will damage the alarm. Ensure
that the same colours are used throughout the premises for Live,
Neutral and Interconnect wires (if used).
WARNING
WARNING
WARNING
The EIB168RC must
NOT
be connected when the house wiring
insulation is being checked with high voltages. i.e. Do
NOT
use a high
voltage insulation tester on the EIB168RC.
WARNING
Alternative Energy Sources (Wind, Solar, UPS, etc.).
This product is designed to be connected to a Pure or True Sine Wave
230 Vac supply. If connecting to a power source that utilises an inverter,
e.g. PV solar panel or UPS, the Total Harmonic Distortion (THD) must
be less than 5%. If in doubt check with manufacturer of the inverter.
Light Dimmer Circuits
This product
must not
be powered from a light dimmer circuit.