High Temperature Alarm
The
DrillTrack G2
Receiver will automatically indicate any DataSonde high temperature alarm
conditions.
When the temperature of the DataSonde reaches 40°C (104F), the Receiver beeps and will display
the information screen for 15 seconds. This is repeated each time the DataSonde temperature reading
increases by 5°C.
When the DataSonde temperature exceeds 75°C (167F) the Receiver will display “
HI
”, until the
DataSonde temperature falls below 40°C (104F).