ALIGNMENT AND ADJUSTMENT
ALIGNMENT OF PLL
Test Equipment Required and Connections
•
DC power supply: 13.8 V
•
DC voltmeter
•
Dummy load (50-ohm)
Alignment Point Locations (Main PCB)
Alignment Procedure
Step
Preset to
Adjustment
Remarks
1
TX 40 CH
L301
Adjust L301 to obtain 3.8 ±0.1 V (DC) at TP3 (R304).
2
TX/RX 1 ~ 40 CH
—
Check if the DC Voltage on all channels is kept within
1.5 V to 3.9 V at TP3.
3
RX 40 CH
CT301
Adjust CT 301 to obtain 16.71 MHz ±50 Hz at TP7 (R216).
4
WX 1 ~ 7 CH
—
Check if the DC Voltage on all channels is kept within
1.0 V to 4.0 V at TP4.
DC CORD
FUSE
ANT
J501
TP7
R216
TP3
R304
L301
TP4
R325
CT301
J502
WA901
GND(BLK)
13.8v(RED)