OPERATION

Under Normal Conditions

Push 

POWER

 down. 

PROTECTED WHEN LIT

and 

GROUNDED WHEN LIT

 light. The connect-

ed devices are under the surge protector's
protection.

Cautions: 

If 

GROUNDED WHEN LIT

 does not light, your

surge protector is not grounded. You must
move it to a different grounded, three-prong
AC outlet.

When the surge protector receives a current
that exceeds its capacity due to overload, the
15-amp circuit breaker at the left side of the
case trips to prevent possible damage, and

RESET

 pops up. 

To resume using the surge protector, discon-
nect one or more of the connected devices,
then push in 

RESET

To turn off the surge protector, press 

POWER

so that it pops up. 

PROTECTED WHEN LIT

 and

GROUNDED WHEN LIT

 go out.

Under Abnormal Conditions

If the surge protector receives an unusually
strong surge, the built-in protection absorbs
the surge to protect your equipment. Howev-
er, if the surge is strong enough, it will deplete
the ability of the protection circuitry. The surge
protector sounds an alarm. 

PROTECTED

WHEN LIT

 goes out. The surge protector's AC

line is no longer protected from surges; re-
place the surge protector.

Содержание network equipment surge protector

Страница 1: ...Detection of Power Surges de tects and protects against a power surge of up to 6 000 volts and 70 500 amps within 1 nanosecond 1 billionth of a second Broadband ADSL Modem Surge Protector provides two line protection against surg es from a connected fax modem or ADSL data connection Safety Alarm sounds a buzzer when the AC line is no longer protected Power Cord with Right Angle Plug en sures secur...

Страница 2: ...our telephones might not ring If ringer oper ation is impaired remove a device from the line Your surge protector complies with Part 68 of FCC Rules You must upon request provide the FCC registration number and the REN to your telephone company Both numbers are on the bottom of the protector Note You must not connect your surge pro tector to coin operated systems party line systems most electronic...

Страница 3: ...hen press the surge protector down to secure it CONNECTIONS 1 Press POWER so that it pops up power off position 2 Connect one end of the existing modular telephone cord to the surge protector s DSL IN jack and the other end to your DSL wall jack Connect one end of a short modular tele phone cord not supplied to the surge protector s DSL OUT jack and the other end to your DSL modem s IN jack 3 Conn...

Страница 4: ... prevent possible damage and RESET pops up To resume using the surge protector discon nect one or more of the connected devices then push in RESET To turn off the surge protector press POWER so that it pops up PROTECTED WHEN LIT and GROUNDED WHEN LIT go out Under Abnormal Conditions If the surge protector receives an unusually strong surge the built in protection absorbs the surge to protect your ...

Страница 5: ... cloth occasionally to keep it looking new Modifying or tampering with the surge protec tor s internal components can cause a mal function and might invalidate its warranty and void your FCC authorization to operate it If your surge protector is not performing as it should take it to your local RadioShack store for assistance If the trouble is affecting the telephone lines the phone company can as...

Страница 6: ... 50 C UL Listed UL1449 UL497A Technical Specifications ADSL Protector Connector RJ11 1 In 1 Out Response Time 1nS Transmission Characteristic Comply with Category 3 PROTECTED WHEN LIT Indicator Lights green when the AC line is protected GROUNDED WHEN LIT Indicator Lights orange when the ground wire is securely connected Protection Mode 1 In 1 Out Tip Ground Ring Ground Alarm Sounds after the AC li...

Страница 7: ...7 NOTES ...

Страница 8: ...urge induced damage to Connected Equipment you must 1 Call RadioShack at 1 888 353 1560 for a return authorization number during the Warranty Period Under no circumstances will a claim for surge in duced damage to Connected Equipment be accepted without a return authorization number 2 Have any surge induced damaged Connected Equipment repaired or get an estimate for repair by a service center auth...

Отзывы: