33
Care
Care
Keep the weather station’s indoor compo-
nents dry; if they get wet, wipe them dry im-
mediately. Use and store the weather
station’s indoor components only in normal
temperature environments. Handle the
weather station carefully; do not drop it.
Keep the weather station away from dust
and dirt, and wipe it with a damp cloth occa-
sionally to keep it looking new.
Modifying or tampering with the weather sta-
tion’s internal components can cause a mal-
function and might invalidate its warranty and
void your FCC authorization to operate it. If
your weather station is not performing as it
should, take it to your local RadioShack store
for assistance.
RESETTING THE MONITOR
Caution: Resetting the monitor also clears
all data stored in the monitor’s memory.
If the monitor’s display locks up or the moni-
tor does not work properly or is receiving
interference, use a pointed object such as a
straightened paper clip to press and release
the
RESET
hole inside the monitor’s battery
compartment. All display segments appear
briefly, then the default time and date (
and
) appear.
Note: Set the correct date, time, and sea lev-
el barometric pressure after you reset the
monitor.
Specifications
Temperature
Operating Measurement:
Indoor ............................................................................................................ 23° to 122°F (–5° to 50°C)
Outdoor ....................................................................................................... –4° to 140°F (–20° to 60°C)
Indoor Measurement Accuracy:
Range: 23° to 32°F (–5° to 0°C) ........................................................................................... ±4°F (±2°C)
Range: >32° to 104°F (0° to 40°C) ....................................................................................... ±2°F (±1°C)
Range: >104° to 122°F (40° to 50°C) ................................................................................... ±4°F (±2°C)
Outdoor Measurement Accuracy:
Range: –4° to <32°F (–20° to 0°C) ....................................................................................... ±4°F (±2°C)
Range: >32° to 104°F (0° to 40°C) ....................................................................................... ±2°F (±1°C)
Range: >104° to 122°F (>40° to 50°C) ................................................................................. ±4°F (±2°C)
Range: >122° to 140°F (>50° to 60°C) ................................................................................. ±6°F (±3°C)
Resolution (Indoor and Outdoor) ........................................................................................ 0.2°F (0.1°C)
Sampling Cycle Frequency:
Indoor ................................................................................................................................... 38 Seconds
Outdoor ................................................................................................................................ 37 Seconds
Resolution (Indoor and Outdoor) .............................................................................................. 0.2 F (0.1 C)