E-108
Troubleshooting
Problem
Possible Cause
Action
See page
Flash memory is corrupted. There
is something wrong with the card.
The keyboard is writing data to its
Flash memory, a SmartMedia card,
or a floppy diskette (WK-3500 only).
Someone may have turned off the
keyboard while data was being
stored in Flash memory or
something else has caused Flash
memory contents to become
corrupted for some reason.
1. The card is write-protected.
2. The card is not inserted correctly
into the card slot.
3. There is not enough space left on
the card.
4. You are trying to use a card whose
voltage or capacity is not
supported by this keyboard.
5. The card is damaged.
1. The card is not inserted correctly
into the card slot.
2. There is not enough space
available in the area into which
you are trying to import the data.
3. You are trying to use a card whose
voltage or capacity is not
supported by this keyboard.
4. The card is damaged.
1. Remove the batteries from the
keyboard and disconnect the AC
adaptor and press the POWER
button.
2. Reload the batteries and/or
reconnect the AC adaptor, and
then press the POWER button
again to turn on power.
3. Use the TRANSPOSE/
FUNCTION button to perform
the system reset operation.
• If this does not solve the
problem, contact your nearest
authorized CASIO Service
Provider to request repair.
Wait until the ongoing operation is
complete and then press the
POWER button again to turn off the
keyboard.
Use the TRANSPOSE/FUNCTION
button to perform the system reset
operation. If this does not correct
the problem, contact your nearest
authorized CASIO Service Provider
to request maintenance.
1. Remove the write-protect sticker
from the card.
2. Correctly insert the card into the
card slot.
3. Use a different card or delete files
you no longer need from the card
you are using.
4. Use only a card of the voltage
and capacity specified for this
keyboard.
5. Use a different card.
1. Correctly insert the card into the
card slot.
2. Delete rhythm, SMF, or tone with
wave data currently in the
keyboard’s Flash memory to
make room from the imported
data.
3. Use only a card of the voltage
and capacity specified for this
keyboard.
4. Use a different card.
E-83
E-22
E-83
E-93
E-94
E-101
E-93
E-94
E-83
E-93
735A-E-110A
The keyboard starts up
abnormally when it is turned
on.
The keyboard does not turn off
when the POWER button is
pressed.
A downloaded tone with
waveform contains noise or
keyboard operations become
abnormal when user data is
selected.
Cannot save data to a card.
Cannot recall data from a card.
WK3000_e_106-112.p65
03.4.8, 11:52
108
Содержание 42-4062
Страница 143: ...735A E 143A WK3000_e_A 19 31 p65 03 4 8 11 53 29...
Страница 144: ...735A E 144A WK3000_e_A 19 31 p65 03 4 8 11 53 30...
Страница 145: ...735A E 145A WK3000_e_A 19 31 p65 03 4 8 11 53 31...