background image

4

Features

A WORD ABOUT 
SAFETY

We have taken every precaution in
designing this multimeter to ensure
that it is as safe as we can make it.
But safe operation depends on you,
the operator. We recommend that
you follow these simple safety rules:

• Never apply voltages to the mul-

timeter that exceed the limits
given in “Specifications” on
Page 6. Never apply more than
500V DC or 500V RMS AC
between any input terminals or
between an input terminal and
ground.

• Use extreme caution when work-

ing with voltages above 40V.
Always disconnect power from
the circuit you are measuring
before you connect test leads to
high-voltage points.

• Never connect the test leads to a

source of voltage when the func-
tion selector is set to 

R

××××

1K

Ω,

R

××××

100

150mA

 

DC mA

, or 

ACA

.

• Always discharge any capacitors

of the circuit under test before
you attach test leads.

• Always turn off power and dis-

connect the test leads from the
circuit you are testing before you
replace the multimeter’s battery.

• Never operate the multimeter

unless its battery compartment

cover is in place and fully closed
with the screw fully tightened.

• Because many AC/DC sets have

a potentially hot chassis, be sure
the top of your workbench and
the floor underneath it are made
of non-conductive materials.

This multimeter is fully calibrated and
tested. Under normal use, no further
adjustment should be necessary ex-
cept as noted in this Owner’s Manual.
If the multimeter requires repair, do
not try to adjust it yourself. Take it to
your local RadioShack store.

WARNINGS: 

• USE EXTREME CAUTION IN

THE USE OF THIS DEVICE.
IMPROPER USE OF THIS
DEVICE CAN RESULT IN
INJURY OR DEATH. FOLLOW
ALL SAFEGUARDS SUG-
GESTED IN THIS OWNER’S
MANUAL IN ADDITION TO
NORMAL SAFETY PRECAU-
TIONS IN DEALING WITH
ELECTRICAL CIRCUITS. DO
NOT USE THIS DEVICE IF YOU
ARE UNFAMILIAR WITH ELEC-
TRICAL CIRCUITS AND TEST-
ING PROCEDURES.

• NEVER TRY TO PROBE WITH

BOTH TEST LEADS AT THE
SAME TIME OR HOLD BOTH
TEST LEADS IN ONE HAND.

• USE EXTREME CARE WHILE

USING THE MULTIMETER TO

Содержание 22-602

Страница 1: ...Owner s Manual Please read before using this equipment Clamp On AC Ammeter with Detachable Multimeter...

Страница 2: ...9 Zero Adjustment 10 Using the Multimeter 10 Making Measurements 10 Measuring DC AC Voltage 11 Measuring Three Phase AC Voltage 12 Measuring AC Voltage Riding on a DC Source Bias 13 Measuring Current...

Страница 3: ...On AC Ammeter lets you measure AC current by simply clamping around a wire quickly and safely Hold Function lets you easily hold the displayed value when measuring AC current so you can see the read...

Страница 4: ...the circuit you are testing before you replace the multimeter s battery Never operate the multimeter unless its battery compartment cover is in place and fully closed with the screw fully tightened Be...

Страница 5: ...MANNER NOT SPECIFIED BY THE MANUFACTURER THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE Special Pane...

Страница 6: ...le length Sensitivity AC DC Voltage 2000 Volt MISCELLANEOUS Operating Temperature 32 to 109 4 F 0 to 43 C Storage Temperature 4 to 140 F 20 to 60 C Power Source One AAA battery Dimensions HWD 77 8 25...

Страница 7: ...7 A Quick Look at Your Multimeter A Quick Look at Your Multimeter OHMS ADJUST left side of AC AMMETER MULTIMETER multimeter OHMS...

Страница 8: ...he battery is properly installed and the back cover is in place and secured Caution Use only a fresh battery of the required size and recommended type Follow these steps to install the bat tery 1 Set...

Страница 9: ...an order re placement leads from your local RadioShack store WARNING ALTHOUGH THE TEST LEADS ARE RATED FOR 1000 VOLTS THE MAXIMUM RATING OF THIS MULTIMETER IS 500 VOLTS DC 500 VOLTS RMS AC DO NOT TRY...

Страница 10: ...nction se lector set to OFF To use the multimeter use the func tion selector to switch between the multimeter s functions Then connect the test leads to the circuit you want to measure MAKING MEASUREM...

Страница 11: ...or to one of the ACV positions to measure AC volt age Note If you are not sure about the voltage level you are measur ing set the function selector to 500 DCV or 500 ACV Then keep trying the next lowe...

Страница 12: ...G THREE PHASE CIRCUITS WE STRONGLY RECOMMEND THAT YOU DO NOT USE THIS MULTIME TER FOR SUCH APPLICATIONS We designed this multimeter primarily to measure household AC voltages If you want to measure 3...

Страница 13: ...rcuit you want to test and note the reading on the upper or lower line of ACVA DCVA on the multimeter 2 Disconnect the test leads from the circuit 3 Remove power from the circuit under test and discha...

Страница 14: ...AGE TO THE TEST LEADS WHILE THE FUNCTION SELECTOR IS SET TO ACA Important Make sure you place only one wire inside the ammeter s jaws at a time If you try to measure AC cur rent in more than one wire...

Страница 15: ...ne of ACVA DCVA on the multimeter If T 3A 15A 30A on the ammeter is set to 3A the AC current is the reading you see For example if the needle points to 2 the AC current is 2 amps If T 3A 15A 30A on th...

Страница 16: ...THE CIRCUIT UNDER TEST HAS ALL POWER REMOVED AND ANY ASSOCIATED CAPACITORS ARE FULLY DIS CHARGED BEFORE YOU MAKE A RESISTANCE MEASUREMENT Caution Never connect the test leads to a source of voltage wh...

Страница 17: ...diately Use and store the multimeter only in normal temperature environments Handle the multimeter carefully do not drop it Keep the multimeter away from dust and dirt Modifying or tampering with the...

Страница 18: ...emove the screw on the upper back of the multimeter Then remove the top cover 3 Use a Phillips screwdriver to remove the screw on the lower back of the multimeter then remove the multimeter s back cov...

Страница 19: ...19 Notes Notes...

Страница 20: ...a product defect during the warranty period take the product and the RadioShack sales receipt as proof of purchase date to any RadioShack store RadioShack will at its option unless otherwise provided...