9.6.2. LEDS
1. LedFan : ON when the Combustion Fan is ON;
2. LedPumpP1 : ON when the Pump P1 is ON.Blinking when the Pump P1 is switched
OFF by the Room Thermostat
;
3. LedPumpP2 : ON when the Valve/Pump P2 is ON.Blinking when the Pump P2 is
switched OFF by the Room Thermostat;
4. LedBoiler:
ON
when the Water temperature is under the value
TH-BOILER[A03]
–
ModulationeDelta1[A05]
.
Blinking
when the Water temperature is over that value
OFF
when the Water temperature is over
TH-BOILER[A03].
5. LedExhaust : ON when Exhaust temperature is over
TH-EXHAUST-ON[F18].
Blinking during the Pre-Extinguishing phase (
Pre-Extinguishing TIME[t06]
)
6. LedChrono : ON when the Chrono Input contact is closed.
7. LedSummer : ON when the selected Season is Summer.
8. LedWinter : ON when the selected Season is Winter.
9. LedFloswitch : ON when the Flowswitch Input contact is closed.
10. LedRoomThermostat : ON when the Room Thermostat Input contact is closed.
9.6.3. DISPLAY
Display\State\Alarms\Temperature : The 4 digit Display visualizes water temperature, the
functioning State of the system and eventual alarms.
State
s’
Codes:
= Off
= Ignition
= Recover ignition
= Modulation 1
= Modulation 2
= Standby
= Safety
= System off with alarms