3. Assembly
3.1 General warnings
The boiler must be set correctly for proper operation!
The boiler is supplied with an external coating containing insulation, 30mm thick. The position
of the silo and the mechanism for transport of pellets is, by default, always on the right side in
regard to the boiler, and it is impossible to change it onto the left. Electrical connections easy
switsh ON easy OFF, and reassembly is not necessary personnel specialized electrical field.
Maximum operating pressure of the boiler is 3 bar, 1 bar the minimum and
maximum operating temperature of the boiler is 110 C.
Boiler with one fan, automation, electric ignition and pump and all of these devices
use 230V power, so that incorrect installation and careless handling may endanger human
life electrocution.
Solid fuel boiler and forced draft should be installed according to valid standards
and legal regulations. Any mechanical or electrical change in the design or installation shall
be deemed a violation of guarantee conditions and will lead to its distortion.
In an assembly the boiler should be properly protected against the excessive
overpressure and overheating.
When installing the hydraulic installation of the boiler must be provided in a
prescribed way of overdraft maximum operating temperature and pressure.
For the proper installation the plumber/installer is responsible.
The manufacturer (Radijator inzenjering) does not take any responsibility coming
from the incorrect installation of the boiler.
When any intervention on the electrical devices Compact 20.1, the whole system off
the main power supply.
The basic requirements to be complied with during the installation
:
-
The boiler can be connected to an open system of central heating, but also to a closed
system of central heating. In case of connection to a closed system, it is recommended to