107
36000 Kraljevo, Živojina Lazića
- Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
factory or workshop of the fireplace,
A brief description of the fault, or lack of,
full address of owner and contact telephone number, e-mail.
7. Regular annual service
Regular service is performed at the end of the heating season in the period from 15.4. to 31.8
and charged by the established price list of the Co. " Radiator Engineering". Service procedure
by the technical persons performing regular annual service, which are authorized by the
manufacturer for this, including the following operations:
NOTE: The Service Provider is in obligation to inspect all of the
following parts ( from the list ) feeder and exchanger, and if it comes to
replacing of any parts of the same, the user receives the above-mentioned
warranty and guarantee for another 12 months placed on the body of the
boiler ( exchanger ). The warranty can be extended up to 5 years from the
date of commissioning. Service and extension of service can be performed by a
person sent by the Central Service of the Co. "Radiator engineering ". For
not changed parts, after the servicing work, the service guarantee is not valid.
dismantling of pellet conveyor from the boiler, checking conveyor and checking bearings
and lubricating;
Bearing must not have difficulty in turning or cracks in the in the housing. Contrarily the
bearing is replaced. If it is determined that the damage to the bearing is due to intrusion
of solid objects into the pellet carrier (due to user’s mistake or the manufacturer of pellet
mistake), Co. “Radiator Engineering” shall charge value of the bearing. If th
e damage to
the bearing is due to the withdrawal of the flame into the pellet transporter itself for
reasons of poorly set parameters when using the boiler, Co. “Radiator Engineering” shall
charge the value of the bearing.
dismantling of combustion cup on combustion chamber and cleaning the space below
combustion cap. Checking condition of combustion cap;
checking and cleaning probe of flue gases;
checking and cleaning fan;
checking the sealing of door;
check the maintenance of the boiler heat exchanger.
dismantling and cleaning of chimney and rear side of exchanger of boiler,
dismantling and cleaning of turbulators and checking condition of turbulators,
checking condition of safety elements (safety valve and air vent).