background image

Symbol Descriptions 

 

The CE mark and Notified Body 
Registration Numbers, the requirement of 
Annex II from Medical Device Directive 
93/42/EEC are met.

 

Indicates this device is subject to the Waste 
Electrical and Electronic 
Equipment Directive in the European Union. 
To protect the environment, dispose of 
useless device at appropriate collection sites 
according to national or local regulations. 

Authorized 
representative in 
the European 
community 

 

Caution 

Please read the instructions for use 

 

Manufacturer 

 

BF type applied part 

Battery Recycling 

 

Paper Recycling

 

Guidance and manufacturer’s declaration – electromagnetic emissions

 

The  TH5xy series  is intended for use in the electromagnetic environment specified below. The customer or the user of the  TH5xy series should 
assure that it is used in such an environment.

 

Emissions test

 

Compliance

 

Electromagnetic environment 

– 

guidance

 

RF emissions 
CISPR 11

 

Group 1

 

The  TH5xy series  uses RF energy only for its internal function. Therefore, its RF 
emissions are very low and are not likely to cause any interference in nearby electronic 
equipment. 

 

RF emissions 
CISPR 11

 

Class B

 

Harmonic emissions 
IEC 61000-3-2

 

Not applicable

 

Voltage fluctuations/ 
flicker emissions 
IEC 61000-3-3

 

Not applicable

 

The  TH5xy series  is suitable for use in all establishments, including domestic 
establishments and those directly connected to the public low-voltage power supply 
network that supplies buildings used for domestic purposes.

 

 

Guidance and manufacturer’s declaration – electromagnetic immunity 

The  TH5xy series  is intended for use in the electromagnetic environment specified below. The customer or the user of the  TH5xy series should 
assure that it is used in such an environment. 

Immunity test 

IEC 60601 test level

Compliance 

level

 

Electromagnetic environment 

– 

guidance

 

Conducted RF 
IEC 61000-4-6 
 
 
Radiated RF 
IEC 61000-4-3 

3 Vrms 
150 kHz to 80 MHz 
 

 

3 V/m 
80 MHz to 2,5 GHz 

Not 

applicable 

 
 
 

3 V/m 

Portable and mobile RF communications equipment should be used no closer to any 
part of the  TH5xy series, including cables, than the recommended separation 
distance calculated from the equation applicable to the frequency of the transmitter. 

 
Recommended separation distance 
                                                                                   
d = 

1,2 

                                                                                                                                 

d = 

1,2 

  80 MHz to 800 MHz

                                                                                           

d = 

2,3 

  800 MHz to 2,5 GHz 

 

where 

is the maximum output power rating of the transmitter in watts (W) according 

to the transmitter manufacturer and 

is the recommended separation distance in 

meters (m). 
 
Field strengths from fixed RF transmitters, as determined by an electromagnetic site 
survey, a should be less than the compliance level in each frequency range b. 

 

Interference may occur in the vicinity of equipment marked with the following symbol:

 

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. 
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption 
and reflection from structures, objects and people. 

a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM 

and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to 
fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the 
TH5xy series  is used exceeds the applicable RF compliance level above, the  TH5xy series  should be observed to verify normal operation. If 
abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the  TH5xy series. 

b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than  3  V/m. 