![AICARE A66 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/aicare/a66/a66_user-manual_2870903001.webp)
1)Non-contact and high-precision body temperature measurement;
2)It can select ℃ or ℉;
Setting method: press the " "key for 8 seconds to switch in the
startup state.
3)Alarm value can be set (the default value of this product is 38℃)
Setting method: the default is set;
4)Beep prompt function (it can set to turn on or turn off the buzzer)
Setting method: press the " "key once to turn on the buzzer in
the startup state;
5)The LCD display with backlight can be used by users in darkness.
Setting method: press the " "key once to turn on the backlight in
the startup state; press the " " key for 8 seconds to convert to
object test in the startup state;
6)Automatic range selection; resolution is 0.1℃ (0.1℉)
7)The latest 32 measured data can be memorized and stored (press
the up and down keys to check the latest 32 stored and measured
data)
8)Automatic data keeping and automatic shutdown
Product Specification
Model: A66
Jiangxi AICARE Medical Technology Co., Ltd.
Table of Contents
1. Description..............................................................................................
2. Safety Manual for Use........................................................................
3. Characteristics.......................................................................................
4. Other Instructions for Use................................................................
5. Notes before Use.................................................................................
6. Product Structure.................................................................................
7. Description of LCD Screen................................................................
8. Scope of Application and Contraindications of Products......
9. Technical Indicators.............................................................................
10. Operating Instructions for Use......................................................
11. Reference Value of Body Temperature.......................................
12. Advice.....................................................................................................
13. Care and Maintenance......................................................................
14. Instructions for Waste Disposal.....................................................
15. Symbol Description............................................................................
16. List of Product Accessories..............................................................
1
1
2
2
3
3
4
4
5
6
7
8
8
9
1 0
1 0
I. Description
II. Safety Manual for Use
Please read this manual carefully before using the infrared
thermometer.
The environment temperature when using this product is
16℃ ~ 35℃.
Please do not place this product in an environment higher than
50℃ or lower than 0℃.
Please do not place this product near charged objects to
avoid electric shock.
Please do not use this product in an environment with relative
humidity greater than 85%.
Please do not place this product too close to the electromagnetic
range. (such as radio, mobile phone, etc.).
Please do not expose this product to the sun, or place it close to
the stove, and not contact with water.
Please do not strike or drop this product, and do not use the
product if it is damaged.
Sweat on forehead, hair, hat or scarf will affect the measuring
accuracy.
Please confirm that the measuring distance is in the range
of 5-10cm.
When forehead sweat or other reasons cause forehead temperature
not to reflect the human temperature normally, please measure the
human temperature from posterior earlobe.
When cleaning is required, wipe the instrument surface gently
with alcohol.
If the product has any problem, please contact with the distributor
rather than repairing the product individually. It is forbidden to
measure the body temperature.
when the environment temperature changes greatly.
-1-
I I I . C h a r a c t e r i s t i c s
I V . O t h e r I n s t r u c t i o n s f o r U s e
-2-
V. Notes before Use
Power On Self-checking
VI. Product Structure
①.Infrared sensor
②.Liquid crystal display (LCD) screen
③.Backlight on/off key
④.Up button (view historical data)
⑤.Down button (view historical data)
⑥.Sound switch key
⑦.Measuring switch
⑧.Battery cover
⑨.Handle
-3-
Figure 1
①
②
③
④
⑤
⑥
⑦
⑧
⑨
VII. Description of LCD Screen
①.Body temperature mode (BODY)
②.Digital reading
③.Storage position
④.Temperature ℃/F
VIII. Scope of Application and
Contraindications of Products
-4-
Figure 2
①
②
③
④
IX. Technical Indicators
1. Basic parameters
Display the accurate digits
0.1℃(0.1℉)
Storage temperature
-20-55℃
Operating environment temperature
16℃~35℃
Relative humidity
≤85%
Power
DC 3V(2 AAA batteries)
Specification
160*100*40mm
Weight
100g
Production date
See the product certificate for details.
2. Measuring range
Model temperature measuring range in human body
32.0-42.9℃
Range of measuring distance
5-10cm
Automatic shutdown
About 20s
3. Measuring accuracy
32.0
℃~
34.9
℃
±0.3℃
35.0
℃~
42.0
℃
±0.2℃
42.1
℃~
42.9
℃
±0.3℃
4. Service life
The service life of the product is 40,000 times, and the product is valid
for 5 years.
5. Software release version
V1.0
-5-
X. Operating Instructions for Use
-6-
This product is a non-contact infrared thermometer that
specializes in measuring the temperature of human forehead,
and the measured temperature will be different according to the
difference of human skin; different measured parts of human can
result in different temperatures as the exposed parts of the
human are greatly affected by the environment temperature.
Infrared thermometer is a thermometer specialized in measuring
the human forehead, it is widely used in families, and this product
cannot replace doctors' diagnosis.
Aim at the target to be tested, press the measuring switch, and LCD
will display all the numbers and characters of the self-checking and a
self-checking screen will appear, as shown in Figure 1 below. This
picture will be displayed for about 1 second.
After the self-checking is completed, a sound of “beep” will be
heard, indicating that the power-on self-checking has been
completed, and the temperature value of the tested target will be
displayed on the LCD.
The product is mainly composed of an infrared sensor, a LCD screen,
a button, a shell, a handle, a battery and a circuit board.
1. Scope of application of products
The body temperature of the tested object is displayed by measuring the
thermal radiation on the forehead.
2. Contraindications of products
1) Birth defects, congenital malformation, septic shock, circulatory failure and
other diseases that may affect forehead temperature measurement seriously.
2) Suffering from mental disorders.
3) Suffering from serious heart, liver and kidney diseases.
6. Working, storage and transportation environment requirements
1) Working environment:
Environment temperature: 16℃ ~ 35℃;
Relative humidity: ≦85%;
Atmospheric pressure: 70 kpa ~ 106 kpa
Power: DC 3V(2 AAA batteries)
2) Storage and transportation environment:
Environment temperature:-20℃ ~+55℃;
Relative humidity: 10% ~ 85%;
No corrosive gas, well ventilated room.
Transportation requirements must conform to regulations of the order
contract, but severe impact, vibration and rain and snow splash during
transportation must be prevented.
1.Battery instructions
An indicating arrow on the ellipse is arranged at the bottom of the
handle; please push the battery cover forwards lightly in the direction
of the arrow with your hand here, and install the battery, so that it can
be tested and used.
Notes of battery installation and replacement:
1) After the battery cover is opened, place the battery at the place
where the battery is installed according to the positive and negative
directions. Pay attention to the correct direction of the positive and
negative electrodes.
2) Wait for 10 minutes to warm up after first using or just placing the
new battery;
3) When the battery capacity is insufficient, the symbol will appear on
the display screen, prompting to replace the new battery. Open the
battery cover (see product structure ⑧) and pay attention to the
positive and negative polarity when replacing the new battery.
Incorrect placement may cause damage to the product.
4) Please take out the battery when the product is not used for a long
time to prolong its service life, and prevent the thermometer from
being damaged due to leakage of battery liquid.
2. Measuring steps of body temperature
1) Aim the thermometer at the middle of forehead (above the
eyebrows) and keep it vertical with a distance of about 5-10cm, and
press the measuring switch to display the temperature immediately.