INSTALLATION INSTRUCTIONS

  

 

GENERAL INSTALLATION REQUIREMENTS 

 

GAS SAFETY 

 

It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 01256.372200) in 

accordance with the regulations listed below.  Failure to install appliances correctly could lead to prosecution.  It is in your own interest and 
that of safety to ensure that the law is complied with.  Failure to have your appliance installed to comply with the installation instructions and 

the requirements listed below could invalidate your guarantee. 

 

RELATED DOCUMENTS 

The installation of the boiler must be in accordance with the relevant requirements of the Gas Safety regulations, Building regulations, I.E.E. 

regulations and the bylaws of the local water authority. 

It should be in accordance also with any relevant requirements of the local authority and the relevant recommendations of the following 

British Standard Codes of Practice: 

 
 

B.S 6400: 

1985  & B.S. 6891 : 1988. 

 

BS 5376: 

Selection and Installation of Gas Space Heating ( 1 and 2 family gases) 

 

 

Part 2:  Boilers of rated input not exceeding 60 Kw 

 

BS 5449: 

Central Heating for domestic premises 

 

 

Part 1:  Forced circulation Hot Water System 

 

CP 342: 

Centralised Hot Water Supply BS 6700 : 

1987 

 

 

Part 2:  Buildings other than individual 

 

BS 5440: 

Flues and air supply for Gas Appliances of rated input not exceeding 

 

 

60 KW (1 and 2 family gases) 

  

Part 

1: 

Flues 

 

 

Part 2:  Air Supply 

 

BS 5446: 

1990:  Installation of Gas Hot Water supplies for domestic purposes 

 

GAS SUPPLY 

Service Pipes:  The local gas region should be consulted at the installation planning stage in order to establish the availability of supply of 

gas.  An existing service pipe must not be used without prior consultation with the local gas region. 
Meters:  A gas meter is connected to the service pipe by the local gas region or local gas region contractor. An existing meter should be 

checked to ensure that it is capable of passing an additional 3.4 m3/hr (125 ft/hr)  before the appliance is installed.  The meter outlet 

governor should ensure a nominal dynamic pressure of 20m Bar, (8 in wg) at the boiler.  Installation pipes should be fitted in accordance 

with BS6891.1988.  

Pipework that supplies the boiler must be a 22 mm. ininterrupted supply from meter to the isolation cock of the 

boiler.

 The complete installation must be tested for soundness as described in the above code, BS 6400: 1985 & BS6891. 

 

IMPORTANT:  BOTH THE USER AND THE MANUFACTURER RELY UPON THE INSTALLER, WHOSE JOB IS TO INSTALL THE BOILER 

AND CONNECT IT TO A CORRECTLY DESIGNED HEATING SYSTEM.  THE INSTALLER SHOULD ACQUAINT HIMSELF WITH THE 
CONTENTS OF THIS PUBLICATION AND THE RELEVANT BRITISH STANDARDS CONCERNING INSTALLATION REQUIREMENTS. 

 

LOCATION OF BOILER 

In siting the combination boiler, the following limitations MUST be observed: 
The position selected for installation should be within the building, and MUST allow  

adequate space for installation, servicing and operation of the combination boiler, and for air circulation around it. The boiler is not suitable 

for external installation. 

This position MUST also allow for a suitable flue termination to be made.  The boiler must be installed on a flat vertical wall which is capable 
of supporting the weight of the combination boiler, and any ancillary equipment. 

If  the boiler is to be fitted in a timber framed building it should be fitted in accordance with the British Gas publication "Guide for Gas 

Installations in Timber Frame Housing, Reference IGE/UP/6. If in doubt, advice must be sought from the local  region of British Gas. 

The boiler may be installed in any room or internal space, although particular attention is drawn to the requirements of the current I.E.E. 
Wiring Regulations, and in Scotland the electrical provisions of the Building Regulations applicable in Scotland, with respect to the 

installation of the boiler in a room or internal space containing a bath or shower. 

Where a room-sealed appliance is installed in a room containing a bath or shower, any electrical switch or appliance control utilising mains 

electricity must be so situated that it cannot be touched by a person using the bath or shower. 

A compartment used to enclose the combination boiler MUST be designed and constructed specifically for this purpose.  An existing 
cupboard, or compartment, may be used provided it is modified accordingly. 

Where installation will be in an unusual location, special procedures may be necessary.  BS 6798 gives detailed guidance on this aspect. 

For clearances to be made available for installation and servicing, see Sections 5.2.2. to 5.2.4. 

 

CONDENSING WALL-HUNG BOILER –  TG05A062.A0505

 

12

Содержание SiRRUS RHA 28

Страница 1: ...Installation and Servicing Instructions RHA 28 Gas Fired Condensing Boilers with Storage Cylinder SEDBUK BAND B CE 0694 TG05A062 A0205 RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH...

Страница 2: ......

Страница 3: ...TION REQUIREMENTS page 12 BOILER INSTALLATION page 16 ELECTRICAL CONNECTIONS page 18 SERVICING AND MAINTENANCE INSTRUCTIONS BOILER CONTROL PANEL page 19 COMMISSIONING page 19 BOILER CONTROL PANEL page...

Страница 4: ...DIRECTIVE 89 336 EEC Electromagnetic compatibility GAS DIRECTIVE 92 42 ECC requirements for new hot water boilers fired with liquid or gaseous fuels All RADIANT boilers are constructed according to U...

Страница 5: ...according to the constructor s instructions Whenever the device is to be put out of service secure all potentially hazardous parts to prevent accidents or damage If the device is sold or transferred...

Страница 6: ...gative effect the operation of the boiler 3 GENERAL WARNINGS BASED ON TYPE OF POWER SUPPLY POWER SUPPLY Electrical safety is achieved only when the device is correctly and efficiently earthed as per c...

Страница 7: ...Max Hot water working pressure bar 6 Min Hot water working pressure bar 0 5 Storage cylinder capacity litres 15 Continuous hot water supply t 30 mixed water litres h 783 Max continuous hot water supp...

Страница 8: ...OVERALL DIMENSIONS 155 715 80 102 75 5 70 78 84 5 900 65 490 160 65 277 200 450 S F G C R A KEY R RETURN FLOW G GAS C HOT WATER F COLD WATER A HEATING FLOW Z SC CONDENSE DRAIN POINT CONDENSING WALL HU...

Страница 9: ...mum flue length 3 mt indicator models 1 1 1 1 2 1 3 2 2 1 2 2 2 3 3 3 1 3 2 3 3 4 4 1 4 2 4 3 5 No diaphragm RHA 28 from 2 a 3 mt from 0 5 to 1 mt from 1 to 2 mt N B remove tags Example intake exhaust...

Страница 10: ...2 93 When deciding the Flue Length he use of additional bends reduce tal length of flue pipe LUE INSTALLATION OPTIONS consider the total length of flue starting by the room seal chamber top connection...

Страница 11: ...e length 30 mt Indicator models 1 1 1 1 2 1 3 2 2 1 2 2 2 3 3 No diaphragm RHA 28 from 1 to 8 mt from 8 to 18 mt from 18 to 30 mt Example intake exhaust pipes length equivalent length 2 5 metres set t...

Страница 12: ...5 80 140 80 S F C R G A 900 84 5 78 70 80 102 75 5 875 The use of additional bends reduce linear length by the following value 90 flue bend 80 wide radius 1 5 m 90 flue bend 80 narrow radius 3 m 45 fl...

Страница 13: ...um flue length 3 mt indicator models 1 1 1 1 2 1 3 2 2 1 2 2 2 3 3 3 1 3 2 3 3 4 4 1 4 2 4 3 5 No diaphragm RHA 28 from 2 a 3 mt from 0 5 to 1 mt from 1 to 2 mt N B remove tags Example intake exhaust...

Страница 14: ...to UNI 7129 01 standard and D P R 412 93 When deciding the Flue Length consider the total length of flue starting by the room seal chamber top connection The use of additional bends reduce linear len...

Страница 15: ...must be a 22 mm ininterrupted supply from meter to the isolation cock of the boiler The complete installation must be tested for soundness as described in the above code BS 6400 1985 BS6891 IMPORTANT...

Страница 16: ...is fitted less than 2m 6 6ft above a balcony above ground or above a flat roof to which people have access the terminal MUST be protected by a purpose designed guard Where the terminal is fitted with...

Страница 17: ...should be installed at the lowest point of the heating circuit and beneath the appliance Note If required an automatic by pass is preferred Radiator valve Filling point DHW outlet Pressure reducing va...

Страница 18: ...6798 2000 Part H I of the Building Regulations give further guidance 3 The discharge pipe should be run in a proprietary drain pipe material e g PVC PVC U ABS PVC C or PP 4 Metal pipework is NOT suit...

Страница 19: ...to the heating system with the fittings Connect pipes and valves as shown in the picture e position the boiler paying attention to hang it to the hanging bracket and make final connections WATER CONN...

Страница 20: ...2000 conversion to allow the boiler to run on LPG to natural gas or vice versa must be carried out by a qualified gas fitter in accordance with law no 46 of 5th March 90 see p 18 ANTI FREEZE SYSTEM A...

Страница 21: ...t to the terminal block located in the instrument panel as follows A Turn off the electrical power supply at the mains B Remove the boiler front casing C Remove the small panel plate A on the right si...

Страница 22: ...HOT WATER SENSOR FAILURE 12 STORAGE TANK WATER SENSOR FAILURE 14 AIR PRESSURE SWITCH WATER PRESSURE SWITCH LOCK OUT 22 REQUEST OF PARAMETERS RE SETTING STARTING UP THE BOILER After connecting up the...

Страница 23: ...4 shows value 04 flashing it is necessary to repeat the procedure of filling the system if the display 14 shows value 01 flashing wait 3 minutes set the ON OFF button 1 to OFF position and then ON pos...

Страница 24: ...DISPLAY PAD ONLY IF OPTIONAL OUTSIDE TEMPERATURE SENSOR IS FITTED 14 TEMPERATURE AND ERROR CODES DISPLAY 13 WATER DEFICIENCY INDICATOR 12 WATER PRESSURE LEVEL 1 BAR INDICATOR 11 WATER PRESSURE LEVEL 1...

Страница 25: ...rature Water Hammer prevention function Short cycling function 3 minutes heating circuit Pump overrun function heating circuit Pump overrun function dom hot water circuit Minimum output setting Maximu...

Страница 26: ...FROST FUNCTION DOMESTIC HOT WATER CIRCUIT THIS FUNCTION COMES INTO OPERATION WHEN THE HOT WATER SENSOR SENSES A 4 C TEMPERATURE THE BOILER STARTS AT THE MINIMUM GAS PRESSURE WITH THE 3 WAY VALVE IN SU...

Страница 27: ...PREVENTION SETTING 00 01 EXCLUDED ACTIVE 2 STANDBY 6 SHORT CYCLING FUNCTION HEATING CIRCUIT FACTORY CALIBRATED AT 180 PARAMETER VALUE 36 00 90 EXPRESSED IN STEPS OF 5 SEC Ex 90 x 5 450 7 5 MIN 7 PUMP...

Страница 28: ...setting j The display will show parameter no k Position ON OFF button 1 first in OFF position and back to ON position 1 Parameter 2setting GAS TYPE SELECTION To modify the Parameter value a Put ON OF...

Страница 29: ...show parameter no k Position ON OFF button 1 first in OFF position and back to ON position 3 Parameter 4 setting PUMP SETTING IN HEATING MODE To modify the Parameter value a Put ON OFF button 1 in OF...

Страница 30: ...tton 1 first in OFF position and back to ON position Parameter 6setting SHORT CYCLING FUNCTION HEATING CIRCUIT adjustable from 0 to 7 5 minutes Factory calibrated at 3 minutes STANDBY To modify the Pa...

Страница 31: ...parameter no 7 k Position ON OFF button 1 first in OFF position and back to ON position Parametr 8setting PUMP OVERRUN DOMESTIC HOT WATER CIRCUIT adjustable from 0 to 7 5 minutes Factory calibrated at...

Страница 32: ...n ON position and wait until the display shows P 0 Gas valve VK 4105G e Release pad 6 and 4 f Keeping pad5 pressed press pad 6 and select parameter no 1 g Release service pad 5 press and release servi...

Страница 33: ...5 to confirm the setting the display will show value 1 k Position ON OFF button 1 in OFF position and back to ON position l Open the hot water tap at the maximum flow and temperature to switch the boi...

Страница 34: ...1 Gas valve VK 4105G g Release service pad 5 press and release service pad 5 h The display will show the parameter value to be set or modified i Press pad 6 to increase or pad 4 to decrease gas press...

Страница 35: ...askets reassemble the entire burner unit Use the soapy water method to check for gas leaks each time gas connections are dismantled and reassembled LEGEND 1 GAS VALVE MOD VK4105A 2 STABILISER 3 INLET...

Страница 36: ...NG NATURAL GAS G20 G P L G 30 G 31 min max max min 6 5 11 4 30 6 SLOW IGNITION ADJUSTMENT This is a slow ignition regulator whose trimmer is factory set to the minimum For adjustment proceed as follow...

Страница 37: ...SEL 14 CIRCULATION PUMP WITH AIR VENT 15 AUTOMATIC AIR VENT 16 HEATING CIRCUIT 3 bar PRESSURE RELIEF VALVE 17 DRAIN TAP 18 WATER PRESSURE GAUGE 19 WATER PRESSURE SWITCH 20 HEATING SENSOR 21 HOT WATER...

Страница 38: ...see the operation mode according to the disk colour red disk heating mode blue disk domestic hot water mode The new 3 way valve does not have the middle position function in case of motor failure DIF...

Страница 39: ...COD 76654LA M4 M2 M1 M12 M10 M8 M9 red black black black black white light blue brown light blue black grey brown light blue brown light blue black brown black brown light blue brown light blue black...

Страница 40: ...5 or to the terminal block fig 3 dotted line on the terminals marked SE SE WARNING The remote control connection cable must pass through a channel which is separate from any system supplied with power...

Страница 41: ...for temperature limit safety sensor for pressure limit Check the exhaust flue safety device Check the max and min modulation pressures and the modulation Check that the electrical connection conforms...

Страница 42: ...n o Thermostat cable disconnected n Check the flue pipe o Check cable connection 04 Water deficiency in the system p Water pressure in the system insufficient stop below 0 5 bar q Water pressure switc...

Страница 43: ...ULTIPLEX GROUP 58014LP MAIN HEAT EXCHANGER 24K 2003 T 58022LA SECONDARY HEAT EXCHANGER 59011LA AIR PRESSURE SWITCH C6065FH1490 59015LA WATER PRESSURE SWITCH PC5411BRASS 73507LA D H W HEATING 1 8 WHITE...

Страница 44: ...ANGE WASHER MPLEX 43139LA PLATE EXCHANGER O RING MULTIPLEX 43145LA 3 WAY VALVE MOTOR O RING MULTIPLEX 43150LA EPDM O RING FOR BRASS CONNECTIONS MULTIPLEX 43151LA BY PASS REGULATOR EPDM O RING 5x2 MULT...

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ...T HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET E OE ALL RIGHTS RE...

Отзывы: