Gas Fire Heater  – Cod. 99963NA – November  2002

 

BOILER OPERATION AND ADJUSTMENT  PROCEDURES FOR USERS 

 

 

Before turning on the boiler read the following warnings carefully . 

Make sure that the warranty booklet carries the stamp of the CORGI registered technician (you can check this by contacting 
corgi on 01256.372200) responsible for installing the boiler. Installation, starting up for the first time, adjustments and 
maintenance operations must all be carried out solely by qualified technicians. Incorrect installation may cause damage to 
persons, animals or property for which the manufacturer cannot be held liable. 
 

WARNING! 

⇒ 

Do not start the boiler unless you are sure it has been thoroughly tested by an authorised technician. 

⇒ 

Check that the regulations regarding air intakes and ventilation of the room where the boiler is installed have been 
fully complied with. 

⇒ 

If the boiler should freeze up, under no circumstances attempt to turn it on but call the RADIANT HELP LINE 
immediately.

 

 

 
 
 
LEGEND: 

 

1. 

ON/OFF SWITCH  

2. 

D.H.W. TEMPERATURE 
SETTING KNOB (40-60°C) 

3. 

POWER INDICATOR  

4. 

D.H.WATER OPERATION 
INDICATOR 

5. 

RESET BUTTON  

 
 
 
 
 

PRELIMINARY OPERATIONS  

-

 Open the gas cock (not supplied as standard)  located immediately upstream of the heater on the gas intake pipe.  

-

 Set switch 1 to 

ON: 

power indicator no. 

3

 will light up. (see fig. 1) 

-

 Open the hot water tap: the d. h. water operation indicator no.

will light up and the exhaust fan will turn on. The electronic 

ignition board will turn on the main burner. When the water demand stops, the burner will turn off and the water heater will 
wait for the next water demand.  

-

 If flame does not ignite, after 10 seconds the gas flow is interrupted and the water heater shuts down.  The indicator no.

5

 will 

light up.  

-

 Shut down requires manual resetting: to restore operation, wait ten seconds and then push reset button 

5

. Re-ignition is 

provided if the main burner accidentally shuts down. The heater will shut down if the burner does not resume operation after 
ten seconds.  

-

 The solenoids will cut gas flow in the vent of electrical failure. When electrical power is restored, repeat the ignition sequence.  

-

 These devices are built to operate with normal water pressure (not exceeding 6 bar), and are equipped with a water 

temperature adjustment knob (40°- 60°C) see fig. 1 no. 

2

MINIMUM 

water temperature (40°C) is obtained by turning temperature knob 2 all the way to the left. 

MAXIMUM 

water temperature (60°C) is obtained by turning temperature knob all the way to the right.  

-

 Whatever the position of the temperature knob, the burner modulates according to flow rate (modulation of flow rate)   

- To put the device out of service, cut electrical power, set switch 1 to OFF and close the gas cock.  

 

  

 
 
 
 
 