background image

USER INSTRUCTIONS

 

 

6

Code 

E21  

General malfunction inside the printed circuit board.  

  Switch off the power supply at the main switch and then switch it on again; 

  When  the error code on the display disappears, the boiler will restart automatically. 

 If the problem persists, 

Call the Service Centre

 

Code 

E22  

Parameter programming request. 

  Switch off the power supply at the main switch and then switch it on again; 

  When  the error code on the display disappears, the boiler will restart automatically. 

 If the problem persists, 

Call the Service Centre. 

 

Code 

E35  

Flame detection malfunction. 

  Press Reset button 

’ on the control panel to reset the error; 

  When  the error code on the display disappears, the boiler will restart automatically. 

 If the problem persists, 

Call the Service Centre.

 

 

Code 

E40  

Electric power supply out of the operation range

Call the Service Centre.

 

 

Code 

F08  

Frost protection function (central heating circuit) ON

Wait for the completion of the operation. 

 

Code 

F09  

Frost Protection function  (D.H.W circuit) ON

Wait for the completion of the operation. 

 

Code 

F28  

Legionella Prevention Function. 

Wait for the completion of the operation. 

 

 

8.  Switching OFF the boiler 

 

To switch the boiler OFF, press   

  INFO button, the word OFF appears on the display. The central 

heating frost protection system remains enabled.  

 

If the boiler was previously ON, it is switched OFF and the fan overrun and pump overrun functions are 
enabled. 

 

N.B. If the boiler is to be left unused for a long period of time,

 the user must do one of the following: 

 

Make the boiler safe

 by disconnecting all the power supplies (electricity and gas), and draining the heating 

system; 

  Leave the boiler in 

standby, 

leaving the electricity and gas supplies connected and, consequently the frost 

protection function. 

Содержание RSA 32/25

Страница 1: ...5 RAD ING MAN UT 1412 1 DIGITECH TR MIAH6 E04 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RSA 32 25 Wall mounted storage combi boiler premix co...

Страница 2: ...arting up the boiler pagina 3 4 INFO Menu pagina 3 5 Boiler functioning modes pagina 4 6 Filling the system pagina 5 7 Diagnostics Error codes pagina 5 8 Switching OFF the boiler pagina 6 9 Frost Prot...

Страница 3: ...not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not attempt to light it unde...

Страница 4: ...ERRORS 3 MODE SELECTION BUTTON SUMMER ONLY WINTER ONLY SUMMER WINTER OFF 4 RESET BUTTON ERROR RESET FLUE TEST FUNCTION ACTIVATION CHIMNEY SWEEPER KEEP IT PRESSED FOR 7 SECONDS 5 DOMESTIC HOT WATER TE...

Страница 5: ...nce pressed the parameter number will appear on the left side of the display and the associated parameter value will appear on the centre of the display Use and buttons of Heating Temperature setting...

Страница 6: ...ion to SUMMER WINTER mode press the MODE SELECTION button 3 fig 1 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by symbols lit c...

Страница 7: ...he display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped Press Reset button on the control panel to reset the erro...

Страница 8: ...0 Electric power supply out of the operation range Call the Service Centre Code F08 Frost protection function central heating circuit ON Wait for the completion of the operation Code F09 Frost Protect...

Страница 9: ...d immediately call the Service Centre 10 Maintenance In order to ensure that the boiler operates efficiently and safely it is recommended that the appliance is inspected by a suitably competent techni...

Страница 10: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION E...

Отзывы: