5.  Boiler functioning modes 

 
“SUMMER” mode 

To  switch  boiler  operation  to  “SUMMER”  mode,  press  the  MODE  SELECTION  button   

 

 

(‘3’  –  fig.  1)

;  The 

boiler  will  only  work  for  the  D.H.W  system,  the  heating  system  is  disabled.  The  “SUMMER”  mode  setting  of  the 

boiler is signalled by the symbol 

, lit continuously on the control panel.  

The automatic ignition system will light the burner every time there is a domestic hot water demand. In this case, 

the symbol 

 will flash on the control panel.  

 
 
“WINTER” mode 

To  switch  boiler  operation  to  “WINTER”  mode,  press  the  MODE  SELECTION  button   

 

 

(‘3’  –  fig.  1)

;  T

he 

boiler  will only  work for the Heating system. The “WINTER” mode setting of the boiler is signalled by the  symbol 

 lit continuously on the control panel. 

The  automatic  ignition  system  will  light  the  burner  every  time  there  is  a  room  heating  demand.  In  this  case,  the 

symbol 

 will flash on the control panel. 

 
 
“SUMMER-WINTER” mode  

To switch boiler operation to “SUMMER-WINTER” mode, press the MODE SELECTION button  

 

 

(‘3’ – fig. 

1)

The  boiler  will  work  for  both  central  heating/D.H.W  systems.  The  “SUMMER-WINTER”  mode  setting  of  the 

boiler is signalled by symbols 

 lit continuously on the control panel. 

The  automatic  ignition  system  will  light  the  burner  every  time  there  is  a  room  heating  or  domestic  hot  water 

demand. The functioning is signalled by the symbols 

 flashing continuously on the control panel

.

 

 

 
Regulating the heating temperature 

The heating temperature is regulated by using  ‘

’ and ‘

’ buttons of 

Heating temperature setting 

 

(‘1’ – 

fig. 1):  

 

Pressing ‘

’ button, reduces the temperature. 

 

Pressing ‘

’ button, increases the temperature. 

The range of temperature settings for the central heating runs from a minimum of 30°C to a maximum of 80°C (25 
°C – 45 °C for under floor heating systems). 

 

 
Regulating the D.H.W temperature  

The D.H.W temperature is regulated by using  ‘

’ and ‘

’ buttons of 

 D.H.W temperature setting  

(‘5’ – 

fig. 1):

 

 

Pressing ‘

’ button, reduces the temperature. 

 

Pressing ‘

’ button, increases the temperature. 

The range of temperature settings for the D.H.W temperature runs from a minimum of 35 °C to a maximum of 60 
°C. 

Содержание RSA 32/25

Страница 1: ...5 RAD ING MAN UT 1412 1 DIGITECH TR MIAH6 E04 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RSA 32 25 Wall mounted storage combi boiler premix co...

Страница 2: ...arting up the boiler pagina 3 4 INFO Menu pagina 3 5 Boiler functioning modes pagina 4 6 Filling the system pagina 5 7 Diagnostics Error codes pagina 5 8 Switching OFF the boiler pagina 6 9 Frost Prot...

Страница 3: ...not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not attempt to light it unde...

Страница 4: ...ERRORS 3 MODE SELECTION BUTTON SUMMER ONLY WINTER ONLY SUMMER WINTER OFF 4 RESET BUTTON ERROR RESET FLUE TEST FUNCTION ACTIVATION CHIMNEY SWEEPER KEEP IT PRESSED FOR 7 SECONDS 5 DOMESTIC HOT WATER TE...

Страница 5: ...nce pressed the parameter number will appear on the left side of the display and the associated parameter value will appear on the centre of the display Use and buttons of Heating Temperature setting...

Страница 6: ...ion to SUMMER WINTER mode press the MODE SELECTION button 3 fig 1 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by symbols lit c...

Страница 7: ...he display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped Press Reset button on the control panel to reset the erro...