MAINTENANCE INSTRUCTIONS
41
P
ARAMETER
P15
–
D.
H
.
W
.
MAXIMUM SET POINT
This parameter is used to set the D.H.W maximum user set
point.
To enter the parameters menu, follow the previously described
procedure (
see paragraph
5.2 ‘Accessing the parameters
menu’
- steps 1-5).
6.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify the value of the parameter within the prescribed
limits (displayed in Celsius degrees):
45 – 75
45–60 (for instantaneous boiler (w/dual circuit exchanger)
7.
Press mode selection button ‘
’ to confirm and to render
the new adjustment operative. The parameter number (P15)
will appear on the display.
8.
To exit from the parameters menu, press simultaneously ‘
’
and ‘
’ buttons.
P
ARAMETER
P16
–
P
OST VENTILATION
This parameter is used to set the fan functioning time, after
switching off the burner.
To enter the parameters menu, follow the previously described
procedure (
see paragraph
5.2 ‘Accessing the parameters
menu’
- steps 1-5.
6.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify the value of the parameter within the prescribed
limits (displayed in minutes):
00 - 10
7.
Press mode selection button ‘
’ to confirm and to render
the new adjustment operative. The parameter number (P16)
will appear on the display.
8.
To exit from the parameters menu, press simultaneously ‘
’
and ‘
’ buttons.
60
P15
00
P16