GENERAL INSTALLATION REQUIREMENTS 

 

GAS SAFETY 

 

It  is  the  law  that  all  gas  appliances  are  installed  by  a  CORGI  registered  installer  (you  can  check  this  by  contacting  corgi  on 
01256.372200) in accordance with the regulations listed below.  Failure to install appliances correctly could lead to prosecution.  It is 

in your own interest and that of safety to ensure that the law is complied with.  Failure to have your appliance installed to comply with 
the installation instructions and the requirements listed below could invalidate your guarantee. 
 

RELATED DOCUMENTS 

The  installation  of  the  boiler  must  be  in  accordance  with  the  relevant  requirements  of  the  Gas  Safety  regulations,  Building 
regulations, I.E.E. regulations and the bylaws of the local water authority. 

It  should  be  in  accordance  also  with  any  relevant  requirements  of  the  local  authority  and  the  relevant  recommendations  of  the 
following British Standard Codes of Practice: 

 
 

B.S 6400: 

1985  & B.S. 6891 : 1988. 

 

BS 5376: 

Selection and Installation of Gas Space Heating ( 1 and 2 family gases) 

 

 

Part 2:  Boilers of rated input not exceeding 60 Kw 

 

BS 5449: 

Central Heating for domestic premises 

 

 

Part 1:  Forced circulation Hot Water System 

 

CP 342: 

Centralised Hot Water Supply BS 6700 : 

1987 

 

 

Part 2:  Buildings other than individual 

 

BS 5440: 

Flues and air supply for Gas Appliances of rated input not exceeding 

 

 

60 Kw (1 and 2 family gases) 

 

 

Part 1:  Flues 

 

 

Part 2:  Air Supply 

 

BS 5446: 

1990:  Installation of Gas Hot Water supplies for domestic purposes 

 

GAS SUPPLY 

Service Pipes:  The local gas region should be consulted at the installation planning stage in order to establish the availability of 
supply of gas.  An existing service pipe must not be used without prior consultation with the local gas region. 
Meters:  A gas meter is connected to the service pipe by the local gas region or local gas region contractor. An existing meter should 
be checked to ensure that it is capable of passing an additional 3.4 m3/hr (125 ft/hr)  before the appliance is installed.  The meter 

outlet governor should ensure a nominal dynamic pressure of 20m Bar, (8 in wg) at the boiler.  Installation pipes should be fitted in 
accordance with BS6891.1988.  

Pipework that supplies the boiler must be a 22 mm. ininterrupted supply from meter to the 

isolation cock of the boiler.

 The complete installation must be tested for soundness as described in the above code, BS 6400: 

1985 & BS6891. 
 

IMPORTANT:  BOTH THE USER AND THE MANUFACTURER RELY UPON THE INSTALLER, WHOSE JOB IS TO INSTALL THE 
BOILER  AND  CONNECT  IT  TO  A  CORRECTLY  DESIGNED  HEATING  SYSTEM.    THE  INSTALLER  SHOULD  ACQUAINT 
HIMSELF  WITH  THE  CONTENTS  OF  THIS  PUBLICATION  AND  THE  RELEVANT  BRITISH  STANDARDS  CONCERNING 

INSTALLATION REQUIREMENTS. 
 

LOCATION OF BOILER 

In siting the boiler, the following limitations MUST be observed: 
The position selected for installation should be within the building, and MUST allow  

adequate space for installation, servicing and operation of the boiler, and for air circulation around it. The boiler is not suitable for 
external installation. 
This position MUST also allow for a suitable flue termination to be made.  The boiler must be installed on a flat vertical wall which is 

capable of supporting the weight of the Vboiler, and any ancillary equipment. 
If  the boiler is to be fitted in a timber framed building it should be fitted in accordance with the British Gas publication "Guide for Gas 

Installations in Timber Frame Housing, Reference DM2". If in doubt, advice must be sought from the local  region of British Gas. 
The boiler may be installed in any room or internal space, although particular attention is drawn to the requirements of the  current 
I.E.E. Wiring Regulations, and in Scotland the electrical provisions of the Building Regulations applicable in Scotland, with respect to 

the installation of the boiler in a room or internal space containing a bath or shower. 
Where a room-sealed appliance is installed in a room containing a bath or shower, any electrical switch or appliance control utilising 
mains electricity must be so situated that it cannot be touched by a person using the bath or shower. 

A compartment used to enclose the boiler MUST be designed and constructed specifically for this purpose.  An existing cupboard, or 
compartment, may be used provided it is modified accordingly. 

Where installation will be in an unusual location, special procedures may be necessary.  BS 6798 gives detailed guidance on this 
aspect. 
For clearances to be made available for installation and servicing, see Sections 5.2.2. to 5.2.4. 

 

Содержание RS 24 E 70/90

Страница 1: ...ADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED ONLY HEATING WALL HUNG BOILERS SYSTEM BOILERS model RS 20 E 40 60 TYPE C ROOM SEALED model RS 24 E 70 90 TYPE C ROOM SEALED SEDBUK BAND D ...

Страница 2: ......

Страница 3: ...TALLATION page 7 BOILER CONTROL PANEL page 9 STARTING UP THE BOILER FOR THE FIRST TIME page 9 MAIN COMPONENTS page 10 OPEN VENTED WATER SYSTEM page 11 SEALED WATER SYSTEM page 12 ELECTRICAL CONNECTIONS page 13 GAS OPERATION AND ADJUSTMENT page 15 GAS TYPE CONVERSION page 16 SHORT LIST OF COMPONENTS page 19 FAULT FINDING CHART page 20 MAINTENANCE page 20 UNPACKING page 20 ...

Страница 4: ...LLATION Warranty expires 12 months from date of installation and in all cases no later than 18 months from date of construction First start up must be performed by authorised personnel only For any operation on the hydraulic gas or electrical circuit regarding the heating unit refer to authorised technicians only and use original spare parts only Wall mounted boilers are not to be installed in dam...

Страница 5: ... Minimum rated output kW 11 20 5 BTU hr 37537 70000 Maximum rated output kW 17 5 26 8 BTU hr 60000 91621 Max working pressure heating bar 3 3 Min working pressure heating bar 0 3 0 3 Max heating temperature C 80 80 Width mm 440 440 Height mm 660 660 Depth mm 260 260 Weight Kg 29 29 Coaxial exhaust flue diameter Double exhaust flue diameter Ø Ø 100 60 80 80 100 60 80 80 Flow return connections Ø 3 ...

Страница 6: ...h insertion of a vertical coaxial collar N B To insert a bend in the flue reduce total flue length by 0 8 m If either flow or return pipe needs to be sided across top of the boiler the additional part number 37015LP packed separately needs to be fitted on top of boiler flue outlet before fitting elbow this will allow pipework to run under flue pipe See Fig 1 Fig 1 137 260 35 G GAS M CENTRAL HEATIN...

Страница 7: ... 45 bend in the flue reduce total flue length by 1 2 m TYPE C WALL MOUNTED BOILERS SEALED COMBUSTION CIRCUIT Kit C Vertical coaxial flue kit system with intake exhaust pipes Ø 118 80 R CENTRAL HEATING RETURN M CENTRAL HEATING FLOW KEY G GAS 35 M 225 137 260 3 4 35 120 440 120 3 4 1 2 450 370 G R 3 4 3 4 80 118 790 max 3000 R CENTRAL HEATING RETURN G GAS M CENTRAL HEATING FLOW KEY 790 137 35 260 35...

Страница 8: ...accordance with BS6891 1988 Pipework that supplies the boiler must be a 22 mm ininterrupted supply from meter to the isolation cock of the boiler The complete installation must be tested for soundness as described in the above code BS 6400 1985 BS6891 IMPORTANT BOTH THE USER AND THE MANUFACTURER RELY UPON THE INSTALLER WHOSE JOB IS TO INSTALL THE BOILER AND CONNECT IT TO A CORRECTLY DESIGNED HEATI...

Страница 9: ...d Where the lowest part of the terminal is fitted less than 2m 6 6ft above a balcony above ground or above a flat roof to which people have access the terminal MUST be protected by a purpose designed guard Where the terminal is fitted within 850mm 34in of a plastic or painted gutter or 450mm 18in of painted eaves an aluminium shield of at least 1000 mm 40in long should be fitted to the underside o...

Страница 10: ...draw a line on the wall on which the boiler will be installed fig 2 2 On the line drawn with the spirit level respecting the distances see fig 1 mark the two points for insertion of the 2 screw anchors or wall anchors for fixing the boiler Choose proper anchors according to the type of wall 3 Hang the boiler fig 3 and make connections to the gas pipe and to the heating system MEASUREMENTS IN mm 44...

Страница 11: ...ed with htg flow and return connecting pipes IMPORTANT Before connecting the heating system pipes carefully clean the system with a flushing agent to prevent residual dirt from entering into circulation and negatively affecting boiler function ADVICE AND SUGGESTIONS FOR DEALING WITH VIBRATIONS AND NOISE FROM THE SYSTEM avoid using pipelines of reduced diameter avoid the use of tight bends and adap...

Страница 12: ...tomatic ignition system will turn the burner ON It may be necessary to repeat the procedure a few times to purge air from pipes Wait 10 seconds and then to reset the boiler turn ON OFF switch to OFF and then ON to reset and try the ignition procedure once again If locking out persists turn boiler OFF and call the RADIANT HELP LINE 01329 828555 TURNING OFF THE BOILER Turn ON OFF switch to OFF posit...

Страница 13: ...4 1 3 2 5 6 7 8 9 10 11 KEY 1 MAIN HEAT EXCHANGER 2 ELECTRONIC IGNITION BOARD S4565QM1012 3 GAS VALVE VK4105 4 BURNER 13 R 5 HEATING SENSOR 1 8 6 LIMIT THERMOSTAT 90 C 7 FLUE HOOD ROOM SEALED 8 ROOM SEALED CHAMBER COVER 9 AIR PRESSURE SWITCH 10 DRAIN TAP 11 EXHAUST FAN ...

Страница 14: ...d wiring must be installed in a way which would not restrict servicing of the boiler f Position isolating valves close to circulating pump g System additives where used corrosion inhibitors and flushing agents descalers should be suitable for all system metals They should be acceptable to British Gas and Water Council approved Non acidity or alkalinity is desirable Pipework The size of flow and re...

Страница 15: ...ystem by means of a connection close to the inlet side of the circulating pump in accordance with the manufacturers instructions the connecting pipe being unrestricted and not less than 15mm 1 2 in nominal size The volume of the vessel should be suitable for the system water content and the air charge pressure should not be less than the system static head Further details of sealed system design c...

Страница 16: ... located in the instrument panel as follows see fig 1 a Unscrew the 2 panel fixing screws under the boiler b Undo the 2 panel side screws using a cross point screwdriver c Pull the plastic panel downwards and rotate it as shown in fig 1 d Remove the protection housing and proceed with electric connections With the electrical control box now open make the following connections see fig 2 Connect the...

Страница 17: ...G 19 20 21 CIRCULATING SUPPLY TERMINAL BLOCK HEARTH L PHASE SL 240 V N NEUTRAL PN PUMP PL 24 7 ELECTRONIC IGNITION BOARD 15 PAR NC EV NO 10 9 M3 SR 14 12 11 13 black blue brown blu marrone light blue black grey ER EA 26 27 25 TS 10 cod 76631LA S4565QM 1012 12 11 9 8 PRINTED CIRCUIT BOARD cod 76646LA SM 20013 M6 M4 M3 M1 M5 M2 M5 22 23 6 4 5 3 2 1 black black brown blue 15 14 16 17 18 M4 RELAY M7 b...

Страница 18: ... P1 MAX HEAT trimmer to the minimum heat by turning it counter clockwise regulate the minimum pressure by turning the P2 MIN GAS trimmer see the table below for calibration pressures on completion set the P1 MAX HEAT trimmer to the required thermal output of the system remove the gauge tighten the pressure socket B and make sure there are no gas leaks N B The P1 MAX HEAT trimmer is factory set to ...

Страница 19: ...eck for gas leaks each time gas connections are dismantled and reassembled d replace the gas setting plate that indicates the type of gas and nominal pressure for the boiler When converting the boiler to work with a different type of gas remove the existing plate and replace it with the new one supplied in the conversion kit e calibrate the new max and min settings for the gas pressure SLOW IGNITI...

Страница 20: ...burner pressure in mbar 0 10000 20000 30000 40000 50000 60000 90000 100000 Btu h G 20 15 C 1013 mbar 5 6 7 8 9 10 11 12 Gas burner pressure in mbar Thermal capacity 0 10000 20000 30000 40000 50000 60000 70000 80000 Btu h 17 6 20 2 70000 80000 0 2 5 5 0 7 6 10 1 12 6 15 1 22 7 25 2 Kw 17 6 20 2 RS 20 E RS 24 E NATURAL GAS 15 C 1013 mbar NATURAL GAS 15 C 1013 mbar ...

Страница 21: ... 60000 70000 80000 90000 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Gas Pressure mbar Thermal Capacity Btu h G 30 31 15 C 1013 mbar RS 24 E 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 Gas Pressure mbar Thermal Capacity Btu h L P G 15 C 1013 mbar L P G 15 C 1013 mbar ...

Страница 22: ... 36066LA ELECTRONIC GAS VALVE VK4105 G1112 3 76631LA ELECTRONIC IGNITION BOARD S4565QM1012 4 76646LA PRINTED CIRCUIT BOARD SM 20013 5 73507LA HEATING SENSOR 1 8 6 37012LA EXHAUST FAN 7 59006LB AIR PRESSURE SWITCH C6065AH1095 8 21001LA BURNER 13 R 1 25 NATURAL GAS 21002LA BURNER 13 R 0 75 NATURAL GAS 21004LA BURNER 13 R 0 70 NATURAL GAS 9 86027LA SAFETY THERMOSTAT 90 C 10 47021LA 2 POSITION COMMUTA...

Страница 23: ... N B It is recommended that the boiler be unpacked before installation The manufacturer cannot be held responsible for any damage caused to the boiler due to incorrect handling of the boiler IMPORTANT The packing materials cardboard are recyclable IMPORTANT The inner packing materials plastic bags polystyrene foam nails etc are potentially dangerous and must not be left within reach of small child...

Страница 24: ...FLET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET E OE ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED SAVED IN STORAGE SYSTEMS OR TRANSMITTED IN ANY FORM OR BY ANY MEANS WHETHER ELECTRONIC MECHANICAL PHOTOCOPYING RECORDING OR OTHERS WITHOUT THE MANU...

Отзывы: