User Manual
Wall Hung Boiler – Cod. 99817NA – July 2001
I
BOILER OPERATION AND ADJUSTMENT PROCEDURES FOR USER
Before turning on the boiler read the following warnings carefully .
Make sure that the warranty booklet carries the stamp of the authorised technician responsible for installing the boiler.
Installation, starting up for the first time, adjustments and maintenance operations must all be carried out solely by qualified
technicians. Incorrect installation may cause damage to persons, animals or property for which the manufacturer cannot be held
liable.
WARNING!
⇒
Do not start the boiler unless you are sure it has been thoroughly tested by an authorised technician.
⇒
Check that the regulations regarding air intakes and ventilation of the room where the boiler is installed have been
fully complied with (see installation instructions pag.2).
⇒
The anti-freeze system will come into operation only if the boiler is in the
winter (
!
!
!
!
) or summer (
"
"
"
"
)
position (with
selector switch 1 in fig. 1 turned to the summer or winter position) and the gas supply turned on. The manufacturer
can accept no responsibility for damage to the boiler caused by lack of observation of these requirements.
⇒
If the boiler should freeze up, under no circumstances attempt to turn it on but call the service centre immediately.
LEGEND
(see fig. 1)
1.
SUMMER-WINTER ON-OFF SWITCH
2.
LOCK-OUT INDICATOR
3.
HEATING TEMPERATURE ADJUSTMENT KNOB
4.
WATER TEMPERATURE ADJUSTMENT KNOB
5.
SPACE FOR ADDING AN OPTIONAL TIMER
SELF- DIAGNOSTIC LEGEND
(see fig. 2)
6.
OPERATING/ POWER INDICATOR
7.
DOMESTIC HOT WATER OPERATION
8.
HEATING OPERATION
9.
FLASHING LIGHT DENOTING AIR PRESSURE
SWITCH FAILURE
10.
FLASHING LIGHT DENOTING DOMESTIC
WATER SENSOR FAILURE
11.
FLASHING LIGHT DENOTING HEATING
SENSOR FAILURE
12.
FLASHING LIGHT DENOTING 90° C MAX
TEMPERATURE SENSOR FAILURE
13.
FLASHING LIGHT DENOTING FLUE SAFETY -
THERMOSTAT FAILURE
14.
FLASHING LIGHT DENOTING LACK OF WATER
IN SYSTEM
15.
WATER PRESSURE LEVEL 1 BAR
16.
WATER PRESSURE LEVEL 1.5 BAR
17.
ELECTRONIC TEMPERATURE INDICATOR
Turning on the electronic ignition:
#
turn on the gas cock situated under the boiler grill;
#
turn selector switch
1
to the
!
symbol denoting winter
(see fig.2);
#
make sure that
6
light is ON (see fig. 2) and the no.
15
or no.
16
lights are ON (see fig. 2); if light no.
14
flashes,
it means water deficiency in the system: open the filling
tap located ander the boiler (see fig. 3) and fill the
system
until a pressure of 1.5 bar has been reached
(light no.
16
ON; see fig. 2) and then
close the filling
tap
.
#
The automatic ignition system will turn the burner on.
It may be necessary to repeat the procedure a few times to purge air from the pipes. To repeat the ignition procedure press
release button
2
(see fig.1) and then try the ignition procedure once again. If the boiler does not start, press the reset button 2
(see fig. 1).
IMPORTANT
should the boiler fail to ignite
wait 3 minutes
before pressing button again.
If locking-out persists, turn boiler OFF and call an authorised radiant service engineer.
2
3
1
4
6
7
8
9
10
11
12
13
14
15
16
17
ELECTRONIC WATER
PRESSURE GAUGE
SELF-DIAGNOSTIC
5
Fig. 1
Fig. 2
Fig. 3