Owner’s Manual – Gas Storage

2

H3958    026271    Rev. A

Pool Heating

This water heater must 

not 

be used for 

pool heating.

Installation Requirements

This water heater must be installed 
by a licensed tradesperson, and in 
accordance with:
•  AS/NZS3500.4 “National Plumbing 

and Drainage Code Hot Water 
Supply Systems – Acceptable 
Solutions”.

•  AS5601/AG601 “Gas Installations”.
•  Local authority regulations.
•  Outside Australia and New Zealand, 

please refer to local plumbing and 
building codes and regulations.

•  Notice to Victorian customers 

from the Victorian Plumbing 
Industry Commission – this water 
heater must be installed by a 
licensed person as required by the 

Victorian Building Act 

(1993). Only 

a licensed person will give you a 
compliance certificate, showing 
that the work complies with all 
the relevant Standards and only a 
licensed person will have insurance 
protecting their workmanship for 6 
years. 

Outdoor Tank Installation

The water heater must be installed 
outdoors, with the minimum clearances 
as shown in the figure below. 

A = 500mm  B=300mm min 

For further details, refer to

 

AS 5601 – Gas Installation Code

 

We recommend a fire-proof plinth 
be installed under the water heater.

Minimum clearance around the windows 
and doors must be maintained – refer to 
AS 5601.

Location

The water heater should be located as 
close as possible to the most frequently 
used hot water outlet. Ensure that the 
data label is clearly visible and that there 
is adequate access for servicing the unit. 

Note

: All models are equipped with a 

sacrificial anode, accessible through the 
top cover. Allow 50% of the height of 

Installation Details

Содержание 135RAD3N

Страница 1: ...Star 135RAD4N 135RAD4L 170RAD4N 170RAD4L 3 and 4 Star Gas Storage Water Heaters H3958 026271 Rev A Installation Details Owner s Information Warranty For advice repairs and service call 1300 365 115 Au...

Страница 2: ...nnections 5 Specifications 6 Commissioning Adjustments 7 Owner s Information 10 System Maintenance 12 Troubleshooting 14 Warranty 16 Other Information 19 Notes 20 Contents Radiant is a registered trad...

Страница 3: ...for all your needs safely economically and for many years to come To be upfront about it we want Radiant to be your brand of choice So you can depend on us to provide more than just a hot water syste...

Страница 4: ...give you a compliance certificate showing that the work complies with all the relevant Standards and only a licensed person will have insurance protecting their workmanship for 6 years Outdoor Tank In...

Страница 5: ...VALVE The drain line from this valve must run in a continuously downward direction in a frost free ambient position with the discharge end left open to atmosphere permanently The PTR Valve is not int...

Страница 6: ...socket on the tank Insulation of Pipes All hot water pipes must be insulated with UV stabilized insulation Temperature Protection All water heaters have the ability to produce hot water very quickly...

Страница 7: ...pipe and clipped into the case The gas control is fitted with a RC 15mm socket A union connection should be used Gas pipe sizes should be in accordance with AS5601 AG601 WARNING Under no circumstances...

Страница 8: ...ef Valve Pressure kPA 1400 1400 1400 1400 Gas Consumption MJ h 135RAD3N 33 135RAD3L 29 170RAD3N 33 170RAD3L 29 135RAD4N 23 5 135RAD4L 22 5 170RAD4N 27 170RAD4L 26 Dimensions mm Height A 1601 1896 1601...

Страница 9: ...this case wait 60 seconds for the gas control to reset 5 Keep the knob depressed for 20 seconds after the pilot flame lights The pilot flame can be observed if a mirror is placed directly below the pi...

Страница 10: ...ms are encountered in this process contact the Dux Service Department Failure to accurately set the pressure can result in damage to the water heater and automatically cancels the Manufacturer s Warra...

Страница 11: ...1 AG601 Ignition System Spark Gap If there is no spark or the spark looks weak adjust as follows 1 Check the gap between the spark electrode and the pilot burner is 3 5mm and adjust as necessary 2 Pus...

Страница 12: ...this appliance DO NOT use store chemicals or flammable materials or spray aerosols near this appliance DO NOT operate with panels or covers removed from the appliance Water Quality Your Dux water hea...

Страница 13: ...ration and settings remain correct What Should I Do During Holidays If the hot water system is not used for two weeks or more a quantity of hydrogen gas which is highly flammable may accumulate in the...

Страница 14: ...s TDS content greater than 600 ppm this service is recommended every 3 years Six Monthly Service By Owner Operate the Pressure Temperature Relief Valve for approximately 10 seconds by operating the ea...

Страница 15: ...ly operate the Pressure Temperature Relief Valve to let air into the heater and allow water to escape through the hose vi Flush the heater until clear water appears then reconnect all fittings fill th...

Страница 16: ...water supply pressure a faulty PTR Valve or a faulty thermostat Contact Dux on 1300 365 115 Insufficient Hot Water Is the Pressure Temperature Relief Valve discharging too much water Do you have the c...

Страница 17: ...Owner s Manual Gas Storage 15 H3958 026271 Rev A Replace faulty tap washers and have your plumber rectify any leaking pipe work Troubleshooting...

Страница 18: ...Replacement Guarantee If an inner cylinder fails on a Dux hot water unit within a further four 4 years after the end of the initial one 1 year warranty period Dux will provide a free replacement hot w...

Страница 19: ...supplied with the Unit and or any relevant statutory requirements In addition to this Warranty certain legislation including the ACL may give you rights which cannot be excluded restricted or modified...

Страница 20: ...cial equipment and or excessive labour at the determination of Dux to make the Unit accessible for repair or replacement As required by legislation including under the ACL any claims for damage to fur...

Страница 21: ...agreed by you the client and Dux Manufacturing Limited Your Details For future convenience fill in the following details and retain with your original invoice for your own records Surname Given Name s...

Страница 22: ...Owner s Manual Gas Storage 20 H3958 026271 Rev A Notes...

Страница 23: ...Owner s Manual Gas Storage 21 H3958 026271 Rev A Notes...

Страница 24: ...ur Water Heater Please take a moment to fill out your details for warranty registration at This will ensure all your current details are registered with us for prompt warranty service if required or u...

Отзывы: