background image

 

Symbol Descriptions 

 

The CE mark and 

Notified Body 

Registration Numbers, 

the requirement of 

Annex II from Medical 

Device Directive 

93/42/EEC are met.

 

 

Please do not dispose of 

the product in the 

household waste at the 

end of its useful life. 

Disposal can take place at 

appropriate collection 

points provided in your 

country. 

Authorized 

representative in 

the European 

community 

 

Caution 

 

Please read the 

instructions for use 

Paper Recycling 

 

Manufacturer 

 

BF type applied part 

 IP22

 

Classification for 

water ingress and 

particulate matter. 

 

To protect the environment, dispose of empty batteries at your retail store or at appropriate collection sites 

according to national or local regulations. 

 

 

Manufacturer’s declaration – electromagnetic immunity 

The  TH2xyz series  is intended for use in the electromagnetic environment (for home healthcare) 
specified below. The customer or the user of the  TH2xyz series  should assure that it is used in 
such an environment. 

Immunity test 

IEC 60601 test 
level
 

Compliance 

level 

Electromagnetic environment – 

guidance 

(for home healthcare environment)

Electrostatic 
discharge(ESD) 
IEC 61000-4-2 

Contact:

±

8 kV   

Air

±

2 kV,

±

4 kV,

±

8 kV,

±

15 kV

 

Contact:

±

8 kV   

Air

±

2 kV,

±

4 kV,

±

8 kV,

±

15 kV

 

Floors should be wood, concrete or 
ceramic tile. If floors are covered with 
synthetic material, the relative humidity 
should be at least 30% 

Power 
frequency(50, 60 
Hz) magnetic field 
IEC 61000-4-8 

30 A/m 

50 Hz or 60 Hz

 

30 A/m 

50 Hz and 60 Hz

The 

TH2xyz series

 power frequency 

magnetic fields should be at levels 
characteristic of a typical location in a 
typical home healthcare environment. 

 

Manufacturer’s declaration – electromagnetic immunity 

The  TH2xyz series  is intended for use in the electromagnetic environment (for home healthcare) 
specified below. The customer or the user of the  TH2xyz series  should assure that it is used in 
such an environment. 

Immunity test 

IEC 60601 test 

level 

Complian

ce level 

Electromagnetic environment – guidance 

(for home healthcare environment)

 

Radiated RF   
IEC 61000-4-3 

10 V/m

 

80 MHz – 2,7 
GHz 

 

80 % AM at 1 
kHz

 

10 V/m

 

80 MHz – 
2,7 GHz 

 

80 % AM at 
1 kHz 

 

Recommended separation distance: 
d = 1,2 

√P

 

d = 1,2 

√P

    80MHz to 800 MHz 

d = 2,3 

√P

    800MHz to 2,7 GHz   

 
Where P is the maximum output power rating of the 
transmitter in watts (W) according to the transmitter 
manufacturer and is the recommended separation 
distance in metres (m). 
 
Field strengths from fixed RF transmitters, as 
determined by an electromagnetic site survey, 

a

 

should be less than the compliance level in each 
frequency range.

 

Interference may occur in the 
vicinity of equipment marked 

with 

the following symbol: 

NOTE1    At 80 MHz and 800 MHz, the higher frequency range applies. 
NOTE2    These guidelines may not apply in all situations. Electromagnetic propagation is affected by 

absorption and reflection from structures, objects and people. 

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and 
land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted 
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an 
electromagnetic site survey should be considered. If the measured field strength in the location in which 
the 

TH2xyz series 

is used exceeds the applicable RF compliance level above, the 

TH2xyz series

 

should be observed to verify normal operation. If abnormal performance is observed, additional measures 
may be necessary, such as re-orienting or relocating the 

TH2xyz series

.

 

 
 
 

Manufacturer’s declaration-electromagnetic emissions

 

The  TH2xyz series  is intended for use in the electromagnetic environment (for home healthcare) 
specified below.The customer or the user of the  TH2xyz series  should assure that it is used in 
such an environment.

 

Emissions test

 

Compliance

 

Electromagnetic environment – guidance

(for home healthcare environment)

RF emissions 
CISPR 11

 

Group 1

 

The  TH2xyz series  uses RF energy only for its internal 
function. Therefore, its RF emissions are very low and are 
not likely to cause any interference in nearby electronic 
equipment. 

 

RF emissions 
CISPR 11

 

Class B

 

The  TH2xyz series  is suitable for use in all 
establishments, including domestic establishments and 
those directly connected to the public low-voltage power 
supply network that supplies buildings used for domestic 
purposes.

 

Отзывы: