Cleaning and Storage:
The Probe Lens is the most delicate part of the thermometer. Use with
care when cleaning the probe lens to avoid damage.
a. Please use alcohol swabs or cotton swabs moistened with 70%~75% alcohol to clean the probe lens.
b. Allow the lens to fully dry for at least 1 minute.
c. Keep the unit dry and away from any liquids and direct sunlight.
d. Clean the probe and probe lens after each use to ensure an accurate reading and avoid cross contamination.
Important Notes:
1. Before the measurement, the subject should stay in a stable environment for 5mins and avoid the exercise, bath for 30mins.
2. Remember to keep the forehead area clean and away from sweat, cosmetics and scar while taking temperature.
3. During the measurement, please away from the direct sunshine and wind.
4. The “Clinical Bias” is -1.4 ~ -1.7°C.
5. The “Limits of Agreement” is 0.98.
6. The "Repeatability" is 0.20°C.
Date of issue: 2020-06-08
Ref No.: 062020
TH05F Non-contact Forehead Thermometer
Intended use: The non-contact forehead thermometer is electronic thermometer using an infrared
detector (thermopile detector) to detect body temperature from forehead center in people of all
ages.
Intended operator: Have eight years of education, no maximum.
Thank you for purchasing this Forehead thermometer. This thermometer is designed with
an advance infrared and ambient temperature compensation technology for accurate and
fast temperature measurements. It also has a wide range mode to scan real time temperature.
It is for home use, not meant to replace a visit to the doctor. Please also remember to compare the measurement result to your regular body
temperature. Please consult with doctor if you have health concerns.
Operating Instructions:
1
Always make sure the probe lens is clean without any damage, and the forehead is clean.
Warning: Choking from swallowing small parts and batteries by children or pets is possible, please keep small parts and batteries at places
where children and pets can’t reach.
2
Power on:
Press the “ON/MEM” button.
3
Mode selection:
3.1
FOREHEAD Mode:
The preset mode of thermometer is forehead. The thermometer is
ready for use after the “
HEAD
” icon stops flashing and two beep sound.
3.2
SURFACE Mode:
In “
Power On
” mode, press and hold the “ON/MEM” button, then press the “SCAN” button
,
the ‘
’ icon will replace
“
HEAD
” icon in the LCD display.
4
Temperature taking:
Note: If there is any temperature difference between the places where the device is stored and where you are going to measure,
subject and the device should stay in the same room for at least 15 minutes before measurement.
Figure 1
4.1 Measuring the FOREHEAD temperature:
You can hold the thermometer within 1 cm from the central forehead (See
Figure 1) and press the “SCAN” button to get the forehead measurement. The time consuming for measurement might be
1 second.
Note: Forehead temperature is displayed in Oral Mode. This mode is an adjusted mode thermometer that converts the
forehead temperature to display its "Oral equivalent." (according to the result of the clinical evaluation to get the
offset value)
4.2 Measuring temperature under SURFACE mode:
When you press the “Scan” button, you will get the temperature immediately about
0.6 sec. If you keep pressing the scan button, the reading of measurement will update continuously.
Note: Surface mode shows the actual, unadjusted temperatures, which is different from the forehead mode.
5 Switching between Fahrenheit(°F) and Celsius(°C):
To change the LCD from °C to °F: In “
Power Off
” mode, press and hold the “SCAN” button, then press the “ON/MEM” button for 3 seconds, icon
“
°C
” will be switched to icon “
°F
”. You can also use the same process to change the LCD display from
°F
to
°C
.
6 Memory Function:
Press the “ON/MEM” button to see the temperature stored. This thermometer provides 25 sets memory for the body
temperature. ** Please notice that only the “HEAD” function’s reading will be recorded.
7 Power off:
Device will automatically shut down after 1 minute pending to extend battery life. At next power on, it will go back to
the default setting of “HEAD” temperature function.
Holding the thermometer too long may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
Fever Indication:
If the thermometer detects a temperature
≥
37.5°C (or 99.5°F) under forehead mode, three short beep sound will follow one long beep sound to
warn the user for potential fever.
Specifications:
Comply with ASTM E1965-98, EN ISO 80601-2-56, IEC/EN60601-1-2(EMC), IEC/EN60601-1(Safety) standards, ISO10993, RoHS.
Temperature measurement range: Forehead mode34~42.2°C (93.2~108°F), Surface mode: -22~80°C (-7.6~176°F)
Accuracy: Forehead mode:
±
0.2°C (0.4°F) within 35~42°C (95~107.6°F), ±0.3°C (0.5°F) for other range.
Surface mode: ±0.3°C(0.5°F) within 22~42.2°C (71.6~108°F), others ±4% or ±2°C(4°F) whichever is greater.
Operating Range
:
10~40°C (50 °F ~104 °F), 15%~85% RH
**Storage temperature range: It should be stored at room temperature between -20~+50°C, RH
≤
85%
Transportation temperature shall be less than 70°C, RH
≤
95%
Atmospheric pressure: 800~1013 hPa
Enclosure Rating: IP22
Dimensions: 94.8 x 35.9 x 24.8 mm
Changing the Battery:
It is supplied with one lithium cell (CR2032x1pcs)
○
1
Loosen the screw on the back housing of anti-clockwise to open the back housing.
○
2
Hold the device and use the screwdriver to flip out the
battery.
○
3
Insert the new battery under the metal hook and press the other side of the battery down until you hear a “click” sound.
○
4
Close the
upper side and then close the bottom side.
○
5
Fasten the screw on the back housing.
Troubleshooting:
Error Message Problem
Solution
Device stabilization in process.
Wait until
stops flashing.
Battery is low and no more measurements are possible.
Replace the battery.
The ambient temperature is not within the range between
10°C and 40°C (50°F~104°F).
Allow the thermometer to rest in a room at least 15 minutes at room
temperature: 10°C~ 40°C(50°F~104°F).
Error 5~9, the system is not functioning properly.
Unload the battery, wait for 1 minute and repower it. If the message
reappears, contact the retailer for service.
Temperature taken is higher than 42.2°C (108.0°F) for
forehead mode or 80°C (176°F) for surface mode.
1) For forehead mode, please stay in a stable environment for 5mins
and avoid the exercise and bath for 30min, then make sure the probe
lens is clean before take a new temperature measurement.
2) For surface mode, please select target within specifications.
If a mal-function still exists, please contact the nearest retailer.
Temperature taken is lower than 34°C (93.2°F) for
forehead mode or –22°C (-7.6°F) for surface mode.
Device can not be powered on to the ready stage.
Change with a new battery.
Warranty:
12 months
Manufacture Date
:
as the serial number (please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E512A000001, the first “E” is External, the second number ”5” is the last number of manufacture year, the third and the fourth number “12” is
the manufacture month, the others is the serial number.
Note: The thermometer is calibrated at the time of manufacture. If you question calibration mode, the accuracy of temperature
measurements or unexpected events at any time, please contact the dealers or nearest service address.
Please report to the manufacturer and the competent authority of the Member State in which you are established about any serious
incident that has occurred in relation to this device.
Warning: No modification of this equipment is allowed.
Please read the instructions for use
BF type applied part
IMPORTER
Company Name?
Company Name?
General Information: Address? Website?
** The thermometer is NOT water-proof. Please
keep the unit dry and away from any liquids.
The device should not submerge into any liquids and expose it to direct moisture.
There is no gender and age limitation for using infrared thermometer.
This is not an AP
or APG product.
Weight: 35.6 grams including battery
Battery life: around 3,000 continuous readings.
Expected Service Life: 4 years
Medical Technology Promedt Consulting GmbH Radiant Innovation Inc.
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany Tel: +886-3-5644185, Fax: +886-3-5644170, E-mail:[email protected]
Add: 1F, No.3, Industrial East 9
th
Rd., Science-Based Industrial Park,
HsinChu, Taiwan Http://www.radiantek.com.tw