RD-30 Operations Manual
Specifications
15
Pickup
Sensor Input Terminal:
4 Pin Lemo
Clamp-On CT Input
Transformer Input
7 Pin Input for Radian Clamp-On Current
3.3 Normal Operating Conditions
Input Potential:
30 - 525 V
AC
at 50Hz (Autoranging)
30 - 630 V
AC
at 60Hz (Autoranging)
V
AC
Not to Exceed (10.5*Frequency)
Input Current Options:
0.02 - 120 Amperes (Autoranging)
0.02 - 200 Amperes (Autoranging)
Clamp-On Current Transformer
Auxiliary Power:
60 - 525 V
AC
at 50Hz (Autoranging)
60 - 630 V
AC
at 60Hz (Autoranging)
V
AC
Not to Exceed (10.5*Frequency)
Power Factor 1.0 to 0.5 (0
°
to -60
°
)
±
0.01% typical,
±
0.04% maximum
Power Factor < 0.5 (-60
°
to -90
°
)
±
(0.1%/ PF) maximum
Operating Temperature:
-20
°
C to 70
°
C (-4
°
F to 158
°
F)
Storage Temperature:
-25
°
C to 80
°
C (-13
°
F to 176
°
F)
Humidity:
0% to 95% non-condensing
Frequency:
45 to 65 Hertz Fundamental
Orientation:
Any
Recalibration Interval:
365 Days
Warm-up:
15 seconds