background image

 

 

MI CT 05 00000 

Series 

EPXB 

BMA #8 PIN CONTACT :  

ASSEMBLY INSTRUCTIONS  

FOR .085 cable 

Issue 

April 12, 12 

Page 

1 / 2 

 

 

 

 

 

 

 

 

 

 

 

 

 

CREATION 
NAME
 : A. LEBOCQ  
DATE : 12/04/2012 
APPR.  

Y. LE GLOAHEC 

ISSUE 

REVISIONS 

NAME 

APPROVED 

 

NOTE: 

 

We recommend a cable thermal preconditioning before assembly.

 

 
STEP 1: 

 

 

Take the tool kit R282 120 000. 

 

Strip the dielectric of the cable up to the center conductor. 

- Stripping tool: R282 051 000. 

 

Trim cable center conductor. 

- Pointer gauge: R282 063 000. 

 

Clean the cable.

 

 
 
 

 
 

 

 

 
 
 

STEP 2: 

 

 

Slide the centering boot or the sealing boot. 

 

Slide the solder sleeve onto the cable. 

 

Position the solder sleeve flush against the solder barrel gauge and solder to the cable or align with the 
outer contact. 

-

 

Solder barrel gauge : R282 744 300. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Center conductor

Diel jacket 

Centering boot 

Sealing boot 

Solder sleeve 

Solder barrel gauge 

Solder detail 

Отзывы: