MI CT 05 00000
Series
EPXB
BMA #8 PIN CONTACT :
ASSEMBLY INSTRUCTIONS
FOR .085 cable
Issue
April 12, 12
Page
1 / 2
CREATION
NAME : A. LEBOCQ
DATE : 12/04/2012
APPR.
Y. LE GLOAHEC
ISSUE
REVISIONS
NAME
APPROVED
NOTE:
•
We recommend a cable thermal preconditioning before assembly.
STEP 1:
•
Take the tool kit R282 120 000.
•
Strip the dielectric of the cable up to the center conductor.
- Stripping tool: R282 051 000.
•
Trim cable center conductor.
- Pointer gauge: R282 063 000.
•
Clean the cable.
STEP 2:
•
Slide the centering boot or the sealing boot.
•
Slide the solder sleeve onto the cable.
•
Position the solder sleeve flush against the solder barrel gauge and solder to the cable or align with the
outer contact.
-
Solder barrel gauge : R282 744 300.
Center conductor
Diel jacket
Centering boot
Sealing boot
Solder sleeve
Solder barrel gauge
Solder detail