29
DISPLAY / CHANGE THE COMFORT TEMPERATURE
The Comfort temperature is shown in the Automatic mode and can be changed by pressing the
or
key.
The Eco temperature, used in programmed mode, cannot be changed and is always the same as the Comfort temperature
-3.5°C. The Antifreeze temperature is also fixed and equal to 7°C.
Note
: The temperature measured by the inner sensor of the product is representative of the ambient temperature nearby it and
it may differ from the temperature measured using other instruments in other areas of the room. That difference may depend
on many factors including, for example:
- the installation position: some areas of the room may be affected by drafts or hot air sacs that modify the sensor measure
-
ment;
- the fixation to an external wall that, being normally colder than internal walls, may imply the measurement of a temperature
lower than the real room temperature;
- unstable conditions: any evaluation must be done in stable working conditions. For this purpose comfort temperature should
be changed only 120min after a previous change . It is not possible, indeed, to evaluate the room temperature maintained by
the product correctly if the comfort level temperature is continually changed in a short time.
If a difference between set temperature and room temperature is detected in stable working conditions, it is possible to adjust
the measurement made by the electronic thermostat of the product. This operation is also particularly useful when installing
the fan heater very close to the floor or ceiling.
To set this correction proceed as follows:
Press and HOLD the
M
key: the display will
show the current time.
While continuing to hold down the
M
key,
press the
and
keys at the same time.
The display shows "AL" (alignment) for 2 secon-
ds and then the actual alignment value (the de-
fault value is 0).
Use the
and
keys to set the desired ali-
gnment by choosing a value between -5 and +5.
Alignment example:
If the product has been set at 19°C but in the
room 20°C is measured in stable conditions, the
alignment to be inserted is equal to 20-19 = 1;
If, on the other hand, the product is set at 19°C
but in the room, for example, 17°C is measured,
the alignment to be set is equal to 17-19 = -2.
Press the
M
button to exit the alignement and re-
sume the normal functioning.