18. Removing the belt in the event of unit failure
In the event that the RolloTron Basic DuoFern 1200 unit
fails and the motor no longer runs, you can use the disen-
gaging bracket provided in order to fully remove the belt
from the belt winder unit, without the need for cutting it.
1.
Remove the mains plug from the
socket.
i
3.
Release the drive with the help of the supplied disen-
gaging bracket. A small amount of resistance must be
overcome when pressing.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron Basic DuoFern 1200 as far
as possible.
5.
Release the belt from the fastening hook and pull
it out completely from the RolloTron Basic DuoFern
1200.
6.
Replace the disengaging bracket in its holder.
WARNING!
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆
Secure the roller shutters from falling.
◆
Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆
Get a second person to help you unlatch the unit.
Drive release
Storage bay
2.
Dismantle the RolloTron Basic DuoFern 1200 as previ-
ously demonstrated on page 88.