10.6 Automatic closing time setting
(can also be configured for RolloPort SX5 DuoFern via HomePilot®)
5. Press "+" and select the
required closing time:
6. Press "P" in order to
store the setting.
After a period of time in use, regularly check to
see whether the door is level when opening/
closing, and whether the spring has enough force
to raise the door.
Add a suitable amount of lubricant to all moving
parts regularly.
1. Press "P" for approx.
5 seconds.
10.7 2000 cycle alarm setting
(can also be configured for RolloPort SX5 DuoFern via HomePilot®)
3. Press "P", the display is "0".
(0 = off = factory setting)
4. Press "+", the display
is "1".
(1 = on)
NOTE!
If this function is activated, after 2000 cycles the drive
will indicate with a short whistling tone at regular
intervals that door maintenance must be carried out.
To end the alarm tone
Switch the power off and back on again, or press the
"
P
" button for 5 seconds.
5. Press "P" in order to save
the setting.
7. Conclude programming
(see page 70 / Method
2) or proceed with next
setting.
6. Conclude programming (see
page 70 / Method 2) or
proceed with next setting.
5 = 150 s
6 = 180 s
7 = 210 s
8 = 240 s
(maximum)
1 = 30 s
2 = 60 s
3 = 90 s
4 = 120 s
2. Press "+"
(if necessary press several
times) until "7" is displayed.