45
EN
Motor types
|
Ø
| Power
1 06
|
35 mm
| 6 Nm
1 10
| 35 mm
| bis 10 Nm
2 10
| 45 mm
| bis 10 Nm
2 20
| 45 mm
| bis 20 Nm
2 30
| 45 mm
| bis 30 Nm
2 40
| 45 mm
| bis 40 Nm
2 50
| 45 mm
| bis 50 Nm
If the installed motor type is unknown, please select:
1 06
for roller shutters with an area of up to 1.5 m
2
2 30
for larger roller shutters
19.3 Menu 9.6 - Configuring the blockage detection
4.
Set and confirm the sensitivity.
Sensitivity:
1 = low
6 = high
i
Test runs should be made to ascertain the highest possible
sensitivity in order to protect the roller shutter in the event
of blockage.
i
It may be necessary to customise the
cut-off sensitivity
depending on the properties of the roller shutter (weight,
running characteristics etc.).
5.
Activate/ deactivate the
reversing function
after a blockage is detected.
On = reversing function on
Off = reversing function off