background image

44

Buttons

Indication in the display

Switching the button lock on or off

Normal display with
active button lock

Automatic

button lock

The button lock function protects
against the settings being altered
unintentionally.
To use the button lock, you must
switch this function on in expert
mode, see page 53, pt. 13 (factory
setting = OFF).

1.

M

OK

+

1.a

Normal display
without button lock

2.

M

OK

+

Switch on the button lock (

)

It is important to press the buttons
in the correct order:

1. 

OK

    +     2. 

M

The automatic button lock is
activated after approx. 2 minu-
tes without any input.

Switch off the button lock (

)

It is important to press the buttons
in the correct order:

1. 

OK

    +     2. 

M

Indication in the display after
pressing the 

M

-button. After this

the lock symbol in the display with
flash for 3 seconds.

ADVICE

Manual operation and switching
over between Auto/Manu is still
possible at any time even when the
button lock is active.

Содержание Fernotron Programming Centre

Страница 1: ...Operating Instructions Fernotron Programming Centre Article No 2411 VBD 369 3 GB 06 09...

Страница 2: ...entre art no 2411 complies with the requirements of the applicable European and national directives The conformity has been certified and the corresponding declarations and documentation are on file a...

Страница 3: ...3 i General view Display Key see page 63 Receiver button Group button UP button OK STOP Stop button data trans mission Menu button OK button Auto Manu Down button Battery compart ment on the rear...

Страница 4: ...r shutters Venetian blinds Electrical consumers e g lighting Operating conditions The Fernotron system may only be operated with and installed in systems and devices in which transmitter or receiver f...

Страница 5: ...g the SET button 40 a Fernotron radio controlled tubular motor with radio code 42 Switching the button lock on or off 44 Expert mode 45 Calling up expert mode 46 Commissioning assistant 47 Selecting g...

Страница 6: ...sists of various transmitters and receivers which allow you to adapt the system flexibly to your requirements Overview of Fernotron system The Fernotron system Group formation With the Fernotron syste...

Страница 7: ...VER Saves the programm data Responds directly to radio command Article no 2420 Receiver surface mouned 2421 Receiver recessed version 2422 Receiver with local switch function 2423 Receiver with sensor...

Страница 8: ...e registered once with each receiver see page 40 Functions The settings function which you can perform with the aid of the Programming Centre can be divided into the following types General functions...

Страница 9: ...ding weekdays weekend programme individual days programme Individual functions apply for each of the maximum of 49 receivers Manual operation of individual roller shutters or devices AUTO MANU switcho...

Страница 10: ...er Call up and carry out the commissioning assistant see page 17 Basic settings via menu navigation with standard switching times including allocation of the names and numbers of the groups and receiv...

Страница 11: ...any changes in the table on page 14 Set the Programming Centre Call up and set the functions in the menu e g Set standard switching times or weekly timer Set the automatic sunlight protection mode dus...

Страница 12: ...You can use names several times To distinguish between receivers with the same name each receiver is given a different receiver number In the living room there are 5 windows and all 5 windows should o...

Страница 13: ...N 27 LAMP 28 FAN 29 AWNING 30 MEDIA ROOM 31 MOTOR 32 NORTH 33 FIRST FLOOR 34 EAST 35 PUMP 36 ROLLER SHUTTER 37 BEDROOM 38 STANDARD LAMP 39 SOUTH 40 PATIO 41 W C 42 STAIRWELL 43 CURTAIN 44 STORE 45 ENT...

Страница 14: ...Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Group Standard pr Wp...

Страница 15: ...Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name Code Name 7 Cod...

Страница 16: ...es No DCF reception or weak DCF reception 1 to 2 lines in the display Confirm and automatically pro ceed with setting clock time and date see page 37 Good DCF reception 3 lines in the display Confirm...

Страница 17: ...navigation Buttons Indication in the display Open the menu 1 M 2 3 Press for approx 2 sec M OK 4 OK 5 OK Select expert mode E The menu item flashes Open expert mode It is important that you press the...

Страница 18: ...r all groups Select a name for each group see page 13 and confirm After each confirmation the next group will follow automatically Select a name for each receiver see page 13 and confirm ADVICE After...

Страница 19: ...nds Register the Programming Cen tre with the receiver and begin data transmission Data transmission will take approx 5 seconds during which a count down from 5 down to 1 will be shown in the display...

Страница 20: ...ta transmission to the last receiver return to the normal display ADVICE Abort initial operation By pressing the menu button the initial operation procedure will be aborted and the normal display will...

Страница 21: ...3 4 5 6 7 8 Call up menu Select functionIf a function is selected then the corresponding symbol will flash Confirm the functionThe setting mode is activated and the value to be set flashes Select the...

Страница 22: ...m function Transmit the time Data transmission Expert mode Automatic SU WI time changeover Set language Button lock Contrast DCF reception quality DCF clock Light function SU WI transmission time Movi...

Страница 23: ...witched off only manual operation is possible AUTO MANU ADVICE Activating deactivating automatic operation for a receiver 2 OK Press for approx 1 sec Select the desired group and receiver Switch autom...

Страница 24: ...us receivers in the group have different settings the AUTO and the MANU indication will appear in the display Activating and deactivating automatic operation AUTO Automatic operation on MANU Automatic...

Страница 25: ...nu AUTO MANU Select the desired group and receiver Activating automatic operation AUTO Deactivating automatic operation MANU Example Group 5 window 3 patio Automatic operation is switched off After ev...

Страница 26: ...d group Then press the E button several times until an A appears in the lower right hand side of the display A all receivers Activating deactivating auto matic operation for the whole group Quit the m...

Страница 27: ...he same switching times for all days of the week ADVICE Buttons Indication in the display Changing the standard switching times for UP DOWN Open the menu 1 M Deactivating of switching times 2 3 4 OK 5...

Страница 28: ...in a switching command Standardschaltzeiten AUF AB Gruppenfunktion The standard switching times are switched off OFF at first when you activate the weekly timer Accordingly only the switching times s...

Страница 29: ...er Select group e g group 5 Select the operating mode Switch off weekly timer or Weekday weekend timer or Individual day timer Confirm the operating mode Set the weekday weekend timer Set the 1 openin...

Страница 30: ...mes for each day of the week from Monday to Sunday Confirm each input with OK Setting the weekly timer 6 M Quit the menu ADVICE If the automatic data transmission was activated in expert mode see page...

Страница 31: ...tic raising and lowering process once a set limiting value has been exceeded Light dependent control Principle of operation ADVICE Radio controlled solar light sensor 2440 Receiver e g 2420 INST SO PO...

Страница 32: ...receiver Activating Deactivating the automatic sunlight mode On ON OFF OFF factory setting If desired select the next recei ver and activate deactivate the automatic sunlight protection mode or Quit t...

Страница 33: ...ered the corresponding postcode in expert mode see page 51 no 8 factory setting 46 Buttons Indication in the display Activating deactivating the automatic dusk mode Open the menu 1 M 2 3 4 5 OK OK The...

Страница 34: ...time incl time delay will be calculated for the current day ADVICE The latest lowering time is 23 59 6 OK 7 M Quit the menu ADVICE If the automatic data transmission was activated in expert mode see p...

Страница 35: ...dom operation Open the menu 1 M 2 3 4 5 OK 6 M OK Select and open automatic random operation Select group and receiver Switch on automatic random operation On ON OFF OFF factory setting If desired sel...

Страница 36: ...Time and date automatically to the receiver To do so you must activate and set the function SU WI transmission time in ex pert mode see page 52 54 IMPORTANT ADVICE Buttons Indication in the display Op...

Страница 37: ...ived then it is not possible to alter the data ADVICE Buttons Indication in the display Setting and transmitting clock time date to receiver Open the menu 1 M 2 3 5 6 OK 4 OK STOP M OK Select and open...

Страница 38: ...pt 20 factory setting OFF You will then be requested in the display to transmit data after every setting In this case you can start the data transmission right from point 6 Recommendation Buttons Ind...

Страница 39: ...motor or switching on the connected light STOP 6 OK 7 OK 8 9 M Confirm data transmission and proceed with the next receiver The programme automatically proposes the next receiver for the data transmi...

Страница 40: ...ting Fernotron system you have the following options 1 Registering with a receiver using the SET button see below 2 Registering with a Fernotron radio controlled tubular motor with radio code see page...

Страница 41: ...u will be re quested to press the Stop button Perform registration This will take 5 seconds during which there will be a countdown from 5 to 1 in the display ADVICE The receiver acknowledges the succe...

Страница 42: ...es Open expert mode It is important to press the buttons in the correct order 1 OK 2 M Select and open the radio code Enter the 5 figure radio code for the tubular motor and confirm each figure with t...

Страница 43: ...Select and open data transmission Select group and or receiver In the display you will the re quested to press the Stop button Perform registration This will take 5 seconds during which there will be...

Страница 44: ...splay without button lock 2 M OK Switch on the button lock It is important to press the buttons in the correct order 1 OK 2 M The automatic button lock is activated after approx 2 minu tes without any...

Страница 45: ...lock on off Setting light function Setting the SU WI transmission time Set the moving text velocity Switch automatic data transmission on and off In expert mode E there are various special functions a...

Страница 46: ...1 M 2 3 M OK Calling up expert mode example 4 5 M OK keep presses for approx 2 sec Select expert mode E The menu item flashes Open expert mode It is important to press the buttons in the correct order...

Страница 47: ...eceiver names 6 Enter standard switching times 7 Register with receiver and transmit data M Press for 4 sec and return to normal display Commissioning assistant 2 Select group and receiver Select and...

Страница 48: ...the radio code you have direct contact with the radio controlled tubular motor You can immediately call up and set the following functions without entering a group or receiver num ber SET function Reg...

Страница 49: ...hange direction of rotation OK STOP 4 b M OK IMPORTANT Do NOT select a group or a recei ver Select and open the Direction of rotation in the expert menu Check the direction of rotation of the motor Ch...

Страница 50: ...firm group and receiver Set the desired end points ADVICE Keep the button depressed until the desired end position is reached then let go of it again The desired end position is now saved As long as t...

Страница 51: ...alteration of the number of groups is possible at any time 10 Define the maximum number of receivers per group 1 to a maximum of 7 receivers per group Select group Set the number of receivers ADVICE S...

Страница 52: ...y setting Despite the lack of a DCF signal the summer winter time changeover will be performed in the Progra mming Centre OFF Off ADVICE A change from summer to winter time and vice versa requires the...

Страница 53: ...d 14 On and OFF On on OFF off factory setting To protect the Programming Centre from inadvertent adjustment you can activate an automatic button lock 2 minutes without input If the automatic button lo...

Страница 54: ...s minutes and confirm Option OFF The SU WI time change over will not be transmitted factory setting 18 OK On and OFF On DCF radio clock on factory setting OFF DCF radio clock off ADVICE Set to OFF if...

Страница 55: ...ivers have received the new time Due to structural restrictions to the radio range it can occasionally happen that a receiver does not receive the time In this case you must transmit the summer winter...

Страница 56: ...ress for 8 seconds Release the buttons M OK 1 Buttons Indication in the display 2 3 The following messages then appear in quick succession Version number and indication of the top row Indication of al...

Страница 57: ...ay 1 STOP 2 3 a 3 b 3 c 4 Select group 5 Set receiver to A for all Example Open all roller shutters Move the roller shutters to the upper end position Stop all roller shutters while they are being rai...

Страница 58: ...number of receivers 49 Ambient conditions Device may only be used in dry rooms Dimensions 54 x 142 x 24 mm Technical data battery change If the batteries are almost empty then a battery symbol flashes...

Страница 59: ...Toulon Italy 142 Bologna 143 Bolzano 144 Florence 145 Genoa 146 Milan 147 Naples 148 Palermo 149 Rome 150 Torino 151 Venice Ireland 152 Cork 153 Dublin 154 Belfast Latvia 155 Riga Lichtenstein 156 Va...

Страница 60: ...adajoz 219 Burgos 220 C ceres 221 Castell n 222 Granada 223 Guadalajara 224 La Coru a 225 L rida 226 Le n 227 Madrid 228 Murcia 229 Oviedo 230 Palma 231 Pamplona 232 San Sebasti n 233 Seville 234 Sant...

Страница 61: ...nal influences such as knocks blows or weather Repairs and modifications performed by unauthorised third parties Use of unsuitable accessories or spare parts Damage caused by inadmissible over voltage...

Страница 62: ...ions excepted Illustrations for information only RADEMACHER Ger te Elektronik GmbH Co KG Buschkamp 7 46414 Rhede Telefon 49 2872 933 171 Telefax 49 2872 933 251 info rademacher de www rademacher de Se...

Страница 63: ...standard switching times Select and open standard switching times 1 M 2 Select group Set opening and closing time 3 OK OK Exit the menu 4 M Select and perform data transmission 5 OK STOP Switch autom...

Страница 64: ...TO MANU switchover Numeric display Factory settings Opening time Closing time for group Standard programme 7 00 20 00 G1 G7 Weekly programme 7 00 20 00 G1 G7 Individual day programme 7 00 20 00 G1 G7...

Отзывы: