8. Description of the configurable parameters
Automatic tilting in sun and ventilation positions:
If the respective parameter is activated, the slats will be automatically
tilted after moving to the corresponding sun or ventilation position
and will be shifted to the default slat position. This function can be
configured separately for the corresponding sun and ventilation
position.
Automatic tilt after moving to a %-position:
If this parameter is activated, the slats will be tilted automatically
and shifted to the default slat position after moving to a specific
%-position (e.g. with the HomePilot®).
Slat run time:
The run time must be recorded and configured for a complete slat
movement. This is necessary in order to be able to correctly move to
a desired slat position from any other position.
In order to record this position, move the blinds / external Venetian
blinds to the central position (with blinds mode switched off). Then
start the motor in the “up” position and record the time required
until the shutter starts to lift. The possible adjustment range is
100 ms - 5000 ms (0.1 s - 5 s).