 GENERAL DESCRIPTION 

 
The  Zond-12e  500A  Ground  Penetrating  Radar  (GPR)  in  operating  condition  consists  of  two 
parts:  Control  Unit  with  built-in  battery  11.1V  8.7  A*h,  integrated  with  antenna  500A,  and 
notebook-type  computer.  (Fig.  1).  The  computer  is  connected  to  the  Control  Unit  via  Ethernet 
cross cable (Fig. 1). The antenna and the Control Unit are fit into plastic case with two runners as 
shown on Fig. 1. Brief description of parts of Zond-12e 500A GPR is given below.   
 

Computer.

 Any computer may be used for the Zond-12e 500A GPR that is a notebook-type, PC 

compatible  computer  with  the  operating  system 

Windows  7  /  8  /  10

,  having  Ethernet  network 

interface  card  10/100BaseT.    The  exchange  of  information  between  the  computer  and  the 
Control  Unit  as  two  peer  elements  of  the  network  is  facilitated  by  utilizing  the 

TCP/IPv4

 

protocol. Therefore, prior to connection of the computer to the  Control Unit you have to set 

IP 

address of computer

 as 

192.168.0.2

 (if this address is occupied or is not accessible, you could 

use any address  from  192.168.0.2 to  192.168.0.254, except  192.168.0.10. 

Please, consult with 

your network administrator before changing IP addresses

). 

Set 

Subnet mask 

as 

255.255.255.0

The  computer  performs  the  following  functions:  it  controls  operation  modes  of  the  GPR,  and 
receives, stores, processes and displays data. 
 

Battery.

 The Zond-12e 500A GPR utilizes Li-Ion battery 11.1 V 8.7 A*h, which is built into the 

case under control panel. The status of the battery (voltage and percentage of the charge balance) 
is displayed on the computer screen in the settings and data receipt menu. In case of the battery 
discharge below the acceptable level, the computer will give a warning signal. Charging of the 
built-in battery is done by using the Mascot 2541 charger, which is supplied with the kit.  
 

Control  Unit  &  Antenna.

  The  general  view  of  the  Control  Unit  is  shown  on  Fig.  1.  It  is 

mounted  on  the  top  of  antenna  500A  and  has  two  outgoing  cables  –  Ethernet  cable  for 
connecting to computer and powering cable to be connected to the control panel. 
 

Antenna.

 The Zond-12e 500A GPR uses shielded high-frequency antenna 500 MHz.  

 
 

2. PREPARING OF THE GPR FOR OPERATION 

 
Connect  the  data  communication  cable  to  the  control  unit  and  to  the  LAN  connector  of  the 
computer as shown in Fig. 1.  
 
Connect  the  powering  cable  to  appropriate  connector  on  the  harness  coming  out  from  control 
panel.  
 

 
 
 

Содержание Zond-12e

Страница 1: ...Zond 12e 500A Ground Penetrating Radar USER S MANUAL Riga 2019 Darzauglu Str 1 105 Riga LV 1012 Latvia Phone Fax 371 67141041 E mail radsys radsys lv Web www radsys lv...

Страница 2: ...consult with your network administrator before changing IP addresses Set Subnet mask as 255 255 255 0 The computer performs the following functions it controls operation modes of the GPR and receives...

Страница 3: ...3 Fig 1 Zond 12e 500A Ground Penetrating Radar in shockproof case Fig 2 View of shock proof case control panel of Zond 12e 500A GPR...

Страница 4: ...the User s Manual for Prism2 program Once the installation is completed you must perform the actions prescribed by the Manual in paragraphs 5 1 and 5 2 Configuring the computer to connect with Zond 12...

Страница 5: ...he same position as on picture To set correct position of signal enter Pulse delay menu item and press A key on keyboard to start automatic adjustment Just adjustment is finished press Enter and then...

Страница 6: ...Zond 12e 500A GPR Just SETUP menu is closed button START is active Press Enter or Space key Display shows data as on picture below To stop data acquisition press Esc key or Enter Space when STOP butto...

Страница 7: ...gher than 40 C it is not recommended to leave the instrument in place where it can be affected by direct sun stares 4 TRANSPORTATION RULES 4 1 In case of observing of rules of packaging of the instrum...

Страница 8: ...ting to Electromagnetic Compatibility and Radio Spectrum Matters 99 5 EC Short range devices Ground and Wall Probing Radars applications Low voltage Directive 73 23 EEC and the Amendment Directive 93...

Страница 9: ...uld void the user s authority to operate the equipment Operation of this device is restricted to law enforcement fire and rescue officials scientific research institutes commercial mining companies co...

Страница 10: ...Domestic United States users The Federal Communications Commission FCC requires that all users of GPR who purchased antennas after July 15th 2002 register their equipment and areas of operation If you...

Страница 11: ...8 2 R glement d Industrie Canada Fran ais Ce dispositif est conforme la norme CNR 220 d Industrie Canada applicable aux appareils radio exempts de licence Son fonctionnement est sujet aux deux condit...

Страница 12: ...12 9 OUR ADDRESS Radar Systems Inc Darzauglu Street 1 105 Riga LV 1012 LATVIA Phone 371 67141041 E mail radsys radsys lv...

Отзывы: