Manual Configuration 

 

For simpler installations, the use of the infra-red may 

not be required. 
 

SpeechPOD can be set up manually by selecting 

the DIL switch settings shown across. Messages, vol-
ume and repeat functions are all programmable . 

 

Of course, timer settings and other high end func-
tions cannot be selected manually. 

1   =   O n   ( u p )       0   =   O f f   ( d o w n )

1

2

3

4

5

6

7

8

In f r a r e d  R e m o t e

E n a b le d

0

D is a b le d

1

S o u n d   O u t p u t   T y p e

A le r t   T o n e

0

S p e e c h

1

M e s s a g e   R e p e a t   P l a y s

1

0

0

( o r   T o n e )

2

0

1

3

1

0

4

1

1

M e s s a g e   S e le c t

1

0

0

0

2

0

0

1

3

0

1

0

4

0

1

1

5

1

0

0

6

1

0

1

7

1

1

0

B a t t e r y   M o n it o r in g

9 V  B a tte r y

0

6 V  B a tte r y

1

S e ttin g :

1

1

0

0

0

0

0

0

IN T E R N A L   S W IT C H   S E T T IN G S

F a c t o r y   D e f a u lt   S e t t in g s :

M a n u a l
IR   R e m o te   D is a b le d ,  S p e e c h   O u tp u t ,  1   M e s s a g e   P la y ,  M e s s a g e   1 ,  9 V   B a tte r y

I n f r a r e d   R e m o t e /P C   O n ly
A u to m a tic   S w itc h   O f f   T im e r :                C o n tin u o u s   O p e r a tio n
M e s s a g e   R e p e a t  D e la y   T im e r :          Z e r o   ( Im m e d ia te   O p e r a tio n )

Product Specifications: 

 

Voltage 

  Internal: 

 9V 

PP3 

Alkaline 

Battery 

   External: 

 6 

– 

12V 

DC 

 Current  

 

Standby Mode:   

90uA @ 9V supply 

   Messaging 

Mode: 

80mA 

@9V 

supply 

PIR Range 

 

0 < 5m with a 70 degree spread 

Temperature 

 

-10 to +50 C 

Humidity 

 

0 – 95% non-condensing 

Sound Output   

89 dBa  max. (Message dependant) 

Weight 

  0.45Kg 

Dimensions 

 

150mm x 100mm x 50mm 

Normally used for wet and slippery floor messages, 

SpeechPOD can be set to play a message whilst the 

floor is wet and then turn off after the timer has reached 

zero. If set at zero SpeechPOD is ON 

USER GUIDE NOTES 

Normally used for setting a delay between message 

plays. In mode 1 SpeechPOD will play the selected mes-

sage immediately on activation, but will then not play 

again until the MODE 1 timer is zero 

NOTE: You cannot use Modes 1 and  2 together 

Normally used for setting a delay between message 

plays. In mode 2 SpeechPOD will not play the selected 

message immediately on activation, but will play it when 

the MODE 2 timer is zero 

NOTE: You cannot use Modes 1 and  2 together 

To avoid message fatigue, the user can program all 

seven messages on the same theme phrased differently. 

With MODE 3 ON each message will be played in turn on 

subsequent activations. 

Used in conjunction with MODE 0. If you do not want 

SpeechPOD to turn off after the time period selected in 

MODE 0, then turning ON MODE 4 will ensure that after 

MODE 0 time out SpeechPOD will not turn off, but will 

default to play message 1. 