background image

The cable shielding must be connected to ground at both ends of the cable.

Label

RJ45

Profinet Color

Tx+

1

Yellow

Tx-

2

Orange

Rx+

3

White

Rx-

6

Blue

Table 2.1: Ethernet wiring instruction.

Note

Connecting the Reset poles for for 0.5 to 2 seconds during operation will cause the sensor

to temporarily use the default IPV4 address 192.168.111.71 until the system is rebooted.

Connecting the Reset poles for longer than 10 seconds during operation will cause the

sensor to reset to default factory settings and reboot. The indicator LED will flash

rapidly during this procedure. Refer to Appendix 3: LED blinking modes for a

description of the LED blinking modes.

Warning

Improper wiring can damage the radar’s communication board. Always check that power

is applied to the right connector before connecting it!

Warning

Make sure the housing of the device is properly connected to the ground reference! Make

sure the electrical resistance of the ground connection is below the maximum prescribed

by local requirements!

Upon powering the system the status LED will turn on and continue to shine while the
system is starting up. When the startup process is completed and the system is running in
normal mode, the LED will blink twice for half a second after which it will remain off for 4
seconds. Any other blinking mode will warn you that the system is not functioning in its
normal mode of operation. See Appendix 3: LED blinking modes for a description of the
different LED blinking modes.

7

Содержание WaveGuide 5 Direction

Страница 1: ...WaveGuide Height Tide User Manual...

Страница 2: ......

Страница 3: ...Version 5 2 1 1 4th of Nov 2020 Applicable for product number WG5 HT CP Related to software versions wht 5 2 1 Radac B V Elektronicaweg 16b 2628 XG Delft The Netherlands tel 31 0 15 890 3203 e mail i...

Страница 4: ......

Страница 5: ...e of the local requirements and regulations for installation of electronic equipment The information in this installation guide is the copyright property of Radac BV the Netehrlands Radac BV disclaims...

Страница 6: ......

Страница 7: ...uration 11 Step 3 1 Set system date and time 11 Step 3 2 Adjust network settings 12 Step 3 3 Sensor configuration 12 Step 4 Perform system check 15 Step 4 1 Check System Information page 15 Step 4 2 C...

Страница 8: ......

Страница 9: ...ompact stainless steel housing The antenna and electronics are the same in both versions but the stainless steel version is easier to handle due to its compact size This manual describes the Compact v...

Страница 10: ......

Страница 11: ...e approval certificate Warning In hazardous areas it is compulsory to Use personal protection and safety gear such as hard hat fire resistive overall safety shoes safety glasses and working gloves Avo...

Страница 12: ...ical distance between the sensor and the obstacle This does not only include horizontal objects in the beam s path but also vertical structures Any structure that the WaveGuide sensors are mounted to...

Страница 13: ...r positioning criteria The outside diameter of the WaveGuide radar cylinder is 219 mm and the total height of the system is 245 mm The radar cylinder has a flange 265 mm diameter that con tains 4 moun...

Страница 14: ...ac can supply an optional cable that com plies with the WaveGuide system requirements for power and data transmission The terminal compartment contains a six pole and a two pole connector as well as a...

Страница 15: ...blinking modes Warning Improper wiring can damage the radar s communication board Always check that power is applied to the right connector before connecting it Warning Make sure the housing of the de...

Страница 16: ...Perform a system check 5 Configure the distribution of data Step 1 Connect the WaveGuide system to a computer Once the WaveGuide system is connected to a Local Area Network communication can be done v...

Страница 17: ...his will cause the sensor to use the default IPV4 address 192 168 111 71 until it is rebooted allowing the user to access and change the network settings to the desired fixed configuration Note In ord...

Страница 18: ...minutes However the web browser may store the login name and password In that case the authorization data will be submitted automatically by the browser without a pop up dialog The default login passw...

Страница 19: ...ed to the Internet as it needs to be able to reach its default NTP servers In the case that the NTP servers can not be reached it is possible to manually set the system date and time using the Date Ti...

Страница 20: ...e For this service to work a connection to the Internet is necessary Note Configuring the use of a static IP could disable the NTP service when the system is not able to reach any nameserver The user...

Страница 21: ...e is no need to modify this parameter Yet in some situations it is advised to set this parameter to a value lower than two times the distance from the radar to the lowest expected water level This is...

Страница 22: ...e quality of the reflection signal that is obtained by the radar After changing the sensor parameters for the radar rebooting the system is required for the changes to take effect The reflection diagr...

Страница 23: ...started a process that can take up to five minutes after power up the displayed status becomes OK Figure 3 6 System information In the same table the ratio between the number of performed and invalid...

Страница 24: ...account such that it does not have a negative effect on the measurements Figure 3 7 The reflection diagram gives a graphical representation of the radar signal received in a single measurement Based...

Страница 25: ...plement the subscription with immediate effect no system reboot is required Default message format The Default format starts a new line for each parameter in the subscription The time used in the Rada...

Страница 26: ...red information parameters spectrum per processing interval The chosen parameters are separated by a semicolon and the 51 spectrum values czz10 are included The NaN string is replaced with a 9999 stri...

Страница 27: ...generate and download the diagnostics file and that it can contain up to 100 kB of data It is recommended to share the diagnostics file with Radac B V because it can help with providing future techni...

Страница 28: ...ge is available on the Radac website http www radac nl The SWAP parameters are calculated every minute using 20 minute data blocks The 20 minute observation block is chosen as a compromise between sho...

Страница 29: ...ding on the size of the log files after clicking a download button it can take up to 3 minutes for the system to compress the files and start the transfer It is also possible to access and transfer th...

Страница 30: ...he highest 1 3 of the waves s H1 10 Average height of the highest 1 10 of the waves cm H1 50 Average height of the highest 1 50 of the waves cm T1 3 Average period of the longest 1 3 of the periods s...

Страница 31: ...bles Name Description Unit Hm0 Significant wave height from M0 cm M0 Band energy from Czz10 f in the range f 30 500 mHz cm2 M0_M Band energy from Czz10 f in the range f 30 1000 mHz cm2 Hm0_M Significa...

Страница 32: ...m Table 5 Time domain parameters Name Description Unit Nwt_zP Sum of periods of waves divided by analysis period Ndlr_H Number of valid sub series of the signal in the vertical direction Ngd_zP Percen...

Страница 33: ...s 24 65 VDC and 8 Watt Power requirements 65 240 VAC and 8 Watt Environmental conditions Ambient temperature 40 to 65 oC Relative humidity 0 100 Ingress protection IP67 Preformance specifications Samp...

Страница 34: ...92 168 111 71 If the connection lasts between 2 and 10 seconds nothing happens During this phase the LED stops blinking After 10 seconds the LED starts blinking again If the connection lasts more than...

Страница 35: ...work is detected Check the network cable connections Blink 2 times The system is working normally This is the default mode Blink 3 times The ip address was set to the default 192 168 111 71 Check chap...

Отзывы: