Flow Cartridge Detail
Figure 9
Re-assembly
10.
Check that flow cartridge seal is in place. Align the cartridge rear tab and body
lug, push the cartridge firmly onto body, and secure with 4 screws. Check that
the outlet retainer is in place on flow cartridge outlet.
Note!
Models prior to August 1995 were fitted with an earlier pattern flow cartridge
having a beige coloured housing. These cartridges did not require the outlet retainer
and used an earlier design (non-slotted) outlet connector which is not interchangeable
with the current flow cartridge (all-black).
11.
Align and refit the body shroud and flow knob assembly, so that the markings
will be visible to the user.
12. Check that lip seal is correctly located in outlet connector,
apply a light
coat of
silicone-only based lubricant,
and carefully refit outlet connector.
Secure with locking pin.
13.
Align and refit flow control cap, and reconnect outlet fittings.
14.
Restore hot and cold supplies and check for any leaks.
Flow Cartridge
Cartridge Retaining
Screws
Body Shroud
Flow Control Knob
Outlet Connector
Flow Control Cap
Locking Pin