15
Exact-3 - Installation
Figure 5
Flat Faced
Insert
Rada Exact-3
Olive
Compression Nut
13 mm
Pipe
Concealing
Plate
Fixing
Screws
2.5 mm A/F
H e x a g o n a l
Wrench
Grub
Screw
Backplate
Assembly
Wall Plug
153 mm
3.
Screw pipe concealing plates onto offset connectors.
Important!
Flush through the hot and cold supplies thoroughly before connection to
shower control. Failure to do so may result in reduced performance and/or product
damage.
2.
Joint offset connectors and screw into sockets so that faced edge is 34 mm
proud of
final
wall surface. If necessary, shorten 1/2" BSP external thread.
Note!
It is essential that inlet supply sockets are parallel, and square with wall surface.
Supplies (pipe centres between 115-165 mm) must terminate in 1/2" BSP internal
sockets to within 3 mm, above or below, the final wall surface.