26
1300905-W2-A
Lubricants
Important! All seals are pre-lubricated. If you need to lubricate the seals, use only a
small amount of silicone-only based lubricants on this product. Do not use oil-based
or other lubricant types as these may cause rapid deterioration of seals.
2
Maintenance Procedure - Cartridge Assembly
Removal
Turn the isolation screw on the isolator valves through 90
o
to isolate the water supplies
to the valve. Open an outlet fitting to release pressure and to assist the draining of
residual water.
3
1
Maintenance Procedures
Maintenance must be carried out in accordance with these instructions, and must be
conducted by designated, qualified and competent personnel.
This mixing valve series is designed for minimal maintenance under conditions of normal use.
External surfaces may be wiped clean with a soft cloth, and if necessary, a mild washing-up
type detergent or soap solution can be used.
Warning!
Many household and industrial cleaning products contain mild abrasives and
chemical concentrates, and should not be used on polished, chromed or plastic surfaces.
Should an internal malfunction occur then this will probably require cartridge renewal. The
cartridge assembly and check valves contain no user-serviceable parts, and must not be
dismantled.
Components are precision-made, so care must be taken while servicing to avoid damage.
When ordering spare parts, please state product type, i.e. Rada 320 IC, and identify part
name and number (refer to
PARTS LIST
). A Seal pack is available, containing all the seals
that may be necessary for renewal during maintenance or servicing.
Содержание 320
Страница 1: ...1 1300905 W2 A 320...
Страница 3: ...3 1300905 W2 A X 1 q X 1 q X 1 q X 1 q 320 IC X 3 q X 2 q X 1 q X 1 q X 2 q...
Страница 4: ...4 1300905 W2 A 320 IF X 1 q X 1 q X 1 q X 1 q X 2 q X 1 q X 1 q X 2 q...
Страница 5: ...5 1300905 W2 A 320 F X 1 q X 1 q X 1 q X 3 q X 1 q...
Страница 6: ...6 1300905 W2 A 320 M X 1 q X 1 q X 1 q X 3 q X 1 q...
Страница 12: ...12 1300905 W2 A a b 6 0 mm 2 1 3 0 mm 6 0 mm 3 0 mm 6 0 mm...
Страница 13: ...13 1300905 W2 A 3 320 IC 320 IF Install the connections...
Страница 14: ...14 1300905 W2 A 320 M 320 F 4 1 min...
Страница 15: ...15 1300905 W2 A 5 3 0 mm 6 320 IC 320 IF Install the pipework a...
Страница 16: ...16 1300905 W2 A 320 M b c 320 F...
Страница 29: ...29 1300905 W2 A...