1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Fig. 4.6: Supply connector
Wire
Ports (7)
Retaining
Screws (2)
Lead
Binding
Screws (7)
Fig. 4.7: Power and Control - cable plug
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Sleep Input
SLEEP IN
SLEEP IN is the digital input for activating the Sleep mode. When
this pin is grounded (for example when connected to pin 3), the
RipEX switches into the Sleep mode. Using Power management
(
Advanced Config.
), the Entering the Sleep mode can be delayed
by a set time. Disconnecting SLEEP IN from GND (-) ends the
Sleep mode. Note that RipEX takes 25 seconds to wake up from
the Sleep mode.
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Alarm Input
ALARM IN
ALARM IN is a digital input. If grounded (e.g. by connecting to
PIN 3), an external alarm is triggered. This alarm can be used
for example to transmit information using SNMP trap, informing
for instance about a power outage or RTU problem. For details
about Alarm management see chapter
Advanced Configuration
.
1
2
3
4
5
6
Pin No.:
7
SI
AI
-
+ A0
+
-
10–30VDC
Alarm Output
max. 30 V DC, 1 A
ALARM OUT
ALARM OUT is a digital output. It can be activated in Alarm
management settings, chapter
Advanced Configuration
. It may
be used for instance to switch on the Fan kit if the preset maxim-
um internal temperature is exceeded or to inform the connected
RTU about a RipEX alarm. If an alarm is triggered, ALARM OUT
is internally connected to GND. If the external device requires
connection to positive terminal of the power supply, PIN 4 should
be used.
PWR
The PWR pins la and - serve to connect a power supply 10–30 VDC. The requirements for a
power supply are defined in Section 6.6, “Power supply” and Section 4.4, “Technical specification”.
RipEX Radio modem & Router – © RACOM s.r.o.