Revision: 05
5.2-8/11
154-625-2
Digital Output Configuration:
Output 1 + 2 (X2.1 - X2.4):
Here up to 8 switching cams can be set (in the example 10 and
990 mm). With the button (ON/OFF) the respective output can
be set on or off.
Hysteresis:
The selected hysteresis number provides a negative and
positive band around the selected switching point. This number
should be selected large enough to avoid shattering of the
output signal and small enough to provide the desired position
accuracy.
Output 3 - 6:
These outputs are not available for EPS02.
Analog Output Configuration:
This function is not available for EPS02.
Thrust Overload:
This function is not available for EPS02.