910161
Hydraulic Rail Drill
Phone: (262) 637-9681
Email:
1.2023 Rev 3.1
Original Instructions
Page 8
Section 2: Specifications and Installation
Specifications
Weight: .......................... 7.6 lbs (3.5 kg)
Length: .......................... 9.0 in (229 mm)
Height: ........................... 9.6 in (243 mm)
Width: ............................ 3.6 in (91 mm)
Chuck Type: .................. 7/16" Quick Chuck
Optimal Pressure: ......... 1000 - 2000 PSI
Flow Range: .................. 4-12 GPM
Optimal flow Range: ...... 4-8 GPM
Operation:...................... Open/Closed option
Motor: ............................ Gerotor
Torque: .......................... 550 ft-lbs
Tool Ports: ..................... #6 SAE O-ring (F)
System fluid temperature must not exceed 140º F (60º C) regardless of operating conditions and/or
system.
Sufficient oil cooling is recommended to limit the system fluid temperature.
Maximum flow must not exceed the recommended rate as noted on the tool specification label. Install a
flow meter in the return line to test the rate of all flow in the system before working the tool.
Operating pressure at the tool must not exceed 2000 lbs/in2 (18.8 MPa). The system relief valve must be
located in the supply circuit between the hydraulic power source and the tool to limit pressure to the tool.
Recommended Hydraulic Fluid
Any non-detergent hydraulic fluid which meets the following specifications may be used:
S.U.S. ............................ @ 100º F (38º C) 140 to 225
@ 210º F (99º C) 40 minimum
Flash Point .................... 340º F (170º C) min.
Pour Point...................... -30º F (-34º C) min.