910115
Loading Arm
Phone: (262) 637-9681
Email:
3.2023 Rev 2.1
Page
7
of
23
Always
make sure that all safety equipment installed properly and are in good working order. Do not
operate the machine until unsafe conditions have been corrected.
Always
operate in a well-ventilated area and make sure that the air filters, air filter covers, and muffler
are in good condition.
Always
keep the machine clean and free of debris. Operate the machine in a safe and responsible
manner. Exercise caution when fueling, working on or near rotating or moving components, hot
components, and fuel systems. Be aware of potential fire hazards and prevent sparks, exhaust, etc., from
starting fires on the machine and/or work area.
Always
comply with all instructions provided on any decals or placards installed on the machine and with
any relevant amplifying information provided in this manual or other general operating procedures.
Always
disconnect the power source and make sure that all controls are in a safe position and install all
appropriate locking and safety devices before doing any of the following:
•
Lubricating
•
Adjusting
•
Installing Tooling
•
Making Repairs
•
Performing Service
Section 2: Specifications and Installation
Specifications
Length ........................... 66.00-78.00 in [167.6-191.1 cm]
Width ............................. 4.75 in [12.0 cm]
Height ............................ 9.00 in [22.8 cm]
Weight ........................... 38.0-lbs [17.2 kg]
Max push ....................... 6.13 tons [5561 kg]
Max pull ......................... 5.15 tons [4675 kg]
Installation
Unpacking Instructions
Upon receiving your Loader Arm
,
promptly remove it from the shipping container. Always keep top
side of container up. Inspect unit for damage which may have incurred during shipping and report it to
carrier for claim.
Testing
1. Using the pump, extend the arm completely.
2. The loading arm is equipped with a pressure gauge.
3. Pump the pressure up to 2500 psi on this model for testing.
4. Return the arm to the fully retracted position.
If the tool fails to function properly see the trouble shooting section of this manual.