- 72 -
7.5 Heating operation logic
Working
status
Working
mode
Water in
temperature-T1
For example,
water in
temperature-T1
Heat pump working level
1
Start-up
of
heat
pump
When you
select the
"Smart
working mode "
T1< Tset-1
T1< 27
℃
Powerful mode-frequency F9
2
Tset-1
≦
T1 < Tset 27
℃≦
T1 <28
℃
Frequency
:
F9 -F8-F7,...,-F2
3
Tset
≦
T1 <Tset+
1
28
℃≦
T1 <29
℃
Silent mode-frequency F2
4
T1
≧
Tset+1
T1
≧
29
℃
HP will be Standby, stop
working till the water in
temperature dropping to less
28
℃
.
5
When you
select
the "Silent
working mode".
T1< Tset
T1< 28
℃
Smart mode -frequency F5.
6
Tset
≦
T1 <
Tset+1
28
℃≦
T1 <
29
℃
Silent mode-frequency F2/F1.
7
T1
≧
Tset+1
T1
≧
29
℃
HP will be Standby, stop
working till the water in
temperature dropping to less
28
℃
.
8
When you
select
the "Powerful
working mode."
T1<Tset+1
T1<29
℃
Powerful mode-frequency
F10/F9
9
T1
≧
Tset+1
T1
≧
29
℃
HP will be Standby, stop
working till the water in
temperature dropping to less
28
℃
.
10
Re-start
to
heat
water in
standby
status
When HP is
working at "
Smart mode"
T1
≧
Tset
T1
≧
28
℃
Standby
11
Tset
>
T1
≧
Tset-1 28
℃>
T1
≧
27
℃
Silent-frequency F2
12
Tset-1
>
T1
≧
Tset-2
27
℃>
T1
≧
26
℃
Frequency
:
F2 -F3-F4,...,-F9
13
<Tset-2
<26
℃
Powerful-frequency F9
14
When HP is
working at "
Silent mode"
≧
Tset
≧
28
℃
Standby
15
Tset
>
T1
≧
Tset-1 28
℃>
T1
≧
27
℃
Silent mode-frequency F2/F1
16
T1<Tset-1
T1<27
℃
Smart -frequency F5
17
When HP is
working at "
Powerful
mode"
T1<Tset-1
T1<27
℃
Powerful -frequency F10/F9
Содержание INVERTER 7
Страница 1: ...POMPE CHALEUR DE PISCINE D RACER INVERTER NOTICE D INSTALLATION ET D UTILISATION...
Страница 2: ......
Страница 6: ...3 2 Dimension 2 1 Dimension Mod les RACER INVERTER 7 9 KW...
Страница 7: ...4 Mod les RACER INVERTER 11 14 16 KW Mod les RACER INVERTER 19 KW 25KW...
Страница 42: ...39 10 Sch ma clat et liste des pi ces d tach es 10 1 Mod le RACER INVERTER 7KW 9KW...
Страница 45: ...42 10 2 Mod le RACER INVERTER 11KW 14KW 16KW...
Страница 49: ...46 10 3 Mod le RACER INVERTER 19KW 25KW...
Страница 53: ...50 Swimming Pool Heat Pump RACER INVERTER...
Страница 57: ...54 2 Dimension 2 1 Dimension RACER INVERTER 7 9 KW...
Страница 58: ...55 RACER INVERTER 11 14 16 KW RACER INVERTER 19 KW 25 KW...
Страница 87: ...84 2 3 The main interface...
Страница 93: ...90 10 Exploded Diagram and spares parts list 10 1 RACER INVERTER 7KW 9KW...
Страница 96: ...93 10 2 RACER INVERTER 11KW 14KW 16KW...
Страница 100: ...97 10 3 RACER INVERTER 19KW 25KW...
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ...CASH PISCINES FRANCE 13 Avenue Neil Armstrong 33700 M rignac A0165RCI02...