8
Flow Requirements
The heater can accept the flow of water from either end, but only by
rotating the heater 180⁰. (See Fig. 6).
DO NOT REVERSE THE FLOW SWITCH.
Left to Right
Flow direction
Fig 6.
The flow rate of water into the heater must not exceed 17,000 litres per
hour (17m3 / hour / 3,740 UK gallons per hour). A higher flow rate will
require the installation of a bypass to prevent damage to the heater
elements. The heater will not operate unless the following minimum flow
rates are achieved:
1,000 litres / hour (1m3/hour / 220 UK gallons/hour) for 2 ~ 6-kW heaters
4,000 litres / hour (4m3/hour / 880 UK gallons/hour) for 9 ~ 24-kW heaters
Water Quality
The water quality
MUST
be within the following limits:
PH 6.8 - 8.0
TA (Total alkalinity) 80—140ppm (parts per million)
Chloride Content MAX: 150 mg/litre
Free Chlorine: 2.0 mg/litre
Total Bromine: Max 4.5 mg/litre
TDS (Total Dissolved Solids) / Calcium hardness 200— 1,000ppm
Stainless Steel heaters are
NOT
suitable for use on saline (salt) water pools.
ONLY
heaters with titanium heating elements are suitable for use on saline
(salt) pools.