Racelogic VBOX NTRIP Скачать руководство пользователя страница 3

8. Press the

Save and restart

button.

Note: Settings are retained after power cycles.

9. When it has connected to the network provider, the

unit will briefly display a

Connected (mobile data

supplier)

message.

The NTRIP modem will reboot and attempt to
connect to the internal modem you have
configured. The settings page will be updated with
the new settings and provide a connection status
indication.

10. Press the

Change settings

button next to the

NTRIP Caster heading to configure the NTRIP
correction service details.

11. Enter the Server Name/IP Address, Port, Mount

Point (correction data stream), Username and
Password information (if required).

Note: These details will be provided by your NTRIP
service provider.

12. Press the

Save b

utton.

If there is a problem with the server details, the
unit will briefly display an

Invalid Caster

Credentials

message.

When it has connected to the NTRIP server, the
unit will briefly display the

RTCM Streaming

message.

The settings page will be updated with the new
settings and a connection status indication
along with the number of data bytes received from
the NTRIP server. The

front display

will also

provide this information.

13. Check that the DIFF

LED

on the VBOX is solid

green, indicating that it is receiving DGPS
corrections.

The modem will reboot and connect. When it is
connected, the unit will briefly display “Wi-Fi
Connected”.

If it cannot connect to the configured Wi-Fi hotspot
on power up, it will automatically restart
and become a configuration access point.

9. Press the

Change settings

button next to the

NTRIP Caster heading to configure the NTRIP
correction service details.

10. Enter the Server Name/IP Address, Port, Mount

Point (correction data stream), Username and
Password information (if required).

Note: These details will be provided by your NTRIP
service provider.

11. Press the

Save b

utton.

If there is a problem with the server details, the
unit will briefly display an

Invalid Caster

Credentials

message.

When it has connected to the NTRIP server, the
unit will briefly display the

RTCM Streaming

message.

The settings page will be updated with the new
settings and a connection status indication
along with the number of data bytes received from
the NTRIP server. The

front display

will also

provide this information.

12. Check that the DIFF

LED

on the VBOX is solid

green, indicating that it is receiving DGPS
corrections.

Note: If you configure it to use both the internal GSM modem and an external Wi-Fi hotspot, it will attempt to auto-

https://en.racelogic.support//ADAS_Testing/ADAS_Hardware/Peripherals/Telemetry_Systems/NTRIP_Modem

3

Отзывы: