2.3 Run a Sample Program
Once the RCM4100/RCM4110 is connected as described in the preceding pages, start
Dynamic C by double-clicking on the Dynamic C icon on your desktop or in your
Start
menu.
If you are using a USB port to connect your computer to the RCM4100/RCM4110, click
on the “Communications” tab and verify that
Use USB to Serial Converter
is selected to
support the USB programming cable. Click
OK
. You may have to determine which COM
port was assigned to the RS-232/USB converter. Open
Control Panel > System > Hard-
ware > Device Manager > Ports
and identify which COM port is used for the USB con-
nection. In Dynamic C, select
Options > Project Options
, then select this COM port on
the
Communications
tab, then click
OK
. You may type the COM port number followed by
Enter
on your computer keyboard if the COM port number is outside the range on the drop-
down menu.
Now find the file
PONG.C
, which is in the Dynamic C
SAMPLES
folder. To run the pro-
gram, open it with the
File
menu, compile it using the
Compile
menu, and then run it by
selecting
Run
in the
Run
menu. The
STDIO
window will open on your PC and will dis-
play a small square bouncing around in a box.
2.3.1 Troubleshooting
If Dynamic C appears to compile the BIOS successfully, but you then receive a communi-
cation error message when you compile and load a sample program, it is possible that your
PC cannot handle the higher program-loading baud rate. Try changing the maximum
download rate to a slower baud rate as follows.
•
Locate the
Serial Options
dialog in the Dynamic C
Options > Project Options >
Communications
menu. Select a slower Max download baud rate.
If a program compiles and loads, but then loses target communication before you can
begin debugging, it is possible that your PC cannot handle the default debugging baud
rate. Try lowering the debugging baud rate as follows.
•
Locate the
Serial Options
dialog in the Dynamic C
Options > Project Options >
Communications
menu. Choose a lower debug baud rate.
If you receive the message
No Rabbit Processor Detected
, the programming cable
may be connected to the wrong COM port, a connection may be faulty, or the target sys-
tem may not be powered up. First, check to see that the power LED on the Prototyping
Board is lit and that the jumper across pins 5–6 of header JP10 on the Prototyping Board is
installed. If the LED is lit, check both ends of the programming cable to ensure that it is
firmly plugged into the PC and the programming header on the RCM4100 with the marked
(colored) edge of the programming cable towards pin 1 of the programming header. Ensure
that the module is firmly and correctly installed in its connectors on the Prototyping Board.
If there are no faults with the hardware, select a different COM port within Dynamic C as
explained for the USB port above. Press
<Ctrl-Y>
to force Dynamic C to recompile the
BIOS. If Dynamic C still reports it is unable to locate the target system, repeat the above
steps for another available COM port. You should receive a
Bios compiled success-
fully
message once this step is completed successfully.