RAB Stealth STL110H Скачать руководство пользователя страница 6

Basic Wiring Diagram

Basic Kit Wiring

Switchplate Label

Multiple fixtures may be wired to a 

single sensor.

To handle loads greater than 1,000 

watts, a qualified electrician 

should install a relay.

Power Quality

It is not recommended to install  

sensors on a circuit that also feeds 

motor loads such as HVAC equip-

ment, kitchen appliances, or garage 

door openers. The Stealth circuit 

is surge and transient protected to 

IEC specifications. However, if  

voltage varies significantly from  

120 volts, sensor may malfunction.

Wiring Diagrams

Power In

Sensor

White

Red

Black

Black

Black

Red

   Red 

(pigtail)

Ground

Ground

White

White

Black

Black

Red

   Red 

(pigtail)

Ground

Ground

White

White

Power In

Power In

5

Switchplate label with 

self-adhesive backing.

Attach Stealth operat-

ing instruction label to 

switchplate for quick 

and easy reference. 

Relay rated to

handle load

required

.1uF

400v DC

capacitor

Power in

   

White   

White   

Power in

   

Black   

Red   

Multiple Fixtures

Note: Pigtail is only used to switch 

remote or additional light fixtures

Содержание Stealth STL110H

Страница 1: ...8 amps Voltage 120 volts 1000 watts Incandescent 500 watts Fluorescent Detection Pattern 50 x 110 Time Adjustment 5 seconds to 12 minutes Power Consumption 1 watt Surge protection I E C specs UL List...

Страница 2: ...ations Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equipment washer dryer or garage door openers Sensor must be below and as far as possible away from light...

Страница 3: ...Sensor will reset to Automatic Mode Will Stealth detect animals Stealth may detect large animals Having animals trigger the sen sor can give property a lived in look However you can limit animal dete...

Страница 4: ...Lens This lens has one Look Out zone and two Look Down zones for excellent detection both at long and close range The Long Range model STL110LRL provides a long narrow protection zone for alleys and...

Страница 5: ...shown in wiring diagram 6 Twist on wire nuts Secure with electrical tape 7 Align gaskets EZ Plate and metal mounting plate to insure proper seal Tighten EZ Plate center screw make sure O Ring gasket...

Страница 6: ...ected to IEC specifications However if voltage varies significantly from 120 volts sensor may malfunction Wiring Diagrams Power In Sensor White Red Black Black Black Red Red pigtail Ground Ground Whit...

Страница 7: ...ore movement to be detected 3 Adjust the sensor aiming as necessary to improve coverage 4 To adjust the sensitivity turn knob gently Less sensitivity counter clockwise may be desired if you wish to de...

Страница 8: ...d by unwanted movement or heat source Solution 1 Aim sensor away from movement or 2 mask lens as in the direction of the source and or 3 lower sensitivity control setting 3 Make sure sensor and lights...

Страница 9: ...ay from the lights 5 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 6 Make sure sensor is not aimed within 20 feet of a road or s...

Страница 10: ...higher ambient light levels turn the photocell control center knob toward the sun symbol 4 Was sensor wired hot If so circuitry may have been damaged 1 Check if sensor is being tricked by reflected l...

Страница 11: ...ounting at 6 feet to 12 feet allows maximum range 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move the sensor 4 Check that move...

Страница 12: ...r mask the lower part of the lens with opaque weatherproof tape to create an Animal Alley 4 Although it is surge and transient protected the sensor may turn on occasionally during extreme voltage surg...

Страница 13: ...is out of warranty or the damage is unrelated to the original manufacture return your unit directly to us with a check for 30 00 made out to RAB Electric We will repair or replace your unit Under no...

Страница 14: ...ccessory Kit Indoor Switchplate Label 3 Wire Nuts Crossbar with Green Ground Screw Hanging Hook 1 2 Close Up Plugs 3 Slotted Screws 4 Finishing Cap O ring Gasket Center Mounting Screw Foam Gaskets 2 M...

Страница 15: ...tion 8AM 6PM ET Mon Fri 24 7 24 7 888 RAB 1000 888 RAB 1232 888 RAB 1236 RAB Lighting 170 Ludlow Avenue Northvale New Jersey 07647 U S A RAB Lighting 2004 14 E mail www rabweb com Questions and reques...

Страница 16: ...OCATIONS Specifications Switching Capacity Voltage Detection Pattern Time Adjustment Power Consumption Surge Protection UL Listing 8 amps 120 volts 300W watts LED 50 x 1000 5 seconds to 12 minutes 1 w...

Страница 17: ...ns Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equiptment washer dryer or garagedoor openers Sensor must be below and as far as possible away from lights Se...

Страница 18: ...ff on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset to Automatic Mode Will STEALTH detect animals STEALTH may detect large animals H...

Страница 19: ...daytime detections without turning on the lights Except during detections which trigger the controlled lights at night the LED remains on and serves as a deterrent indicating a security device in ope...

Страница 20: ...sensor To handle loads greater than 300W watts a qualified electrician should install a relay Switchplate Label Switchplate label has self adhesive backing Power Quality It is not recommended to inst...

Страница 21: ...ntil lights go on As distance from the sensor increases it will take more movement to be detected Aiming andWalkTesting Start Finish 3 Adjust the sensor aiming as needed to improve coverage 4 To adjus...

Страница 22: ...the sensor Create an Animal Alley by aiming sensor or masking the lower portion of the lens with opaque weather proof tape to reduce triggering 10 50 Animal Alley 4 Although it is surge and transient...

Страница 23: ...s properly with bag covering check item 4 7 Problem Sensor is triggered by unwanted movement or heat source Solution Aim sensor away from movement Mask lens in the direction of source Lower sensitivit...

Страница 24: ...rom the lights 5 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 6 Make sure sensor is not aimed within 20 ft of a road or sidewal...

Страница 25: ...ensor s view The sensor s photocell may detect the light and deactivate For operation at higher ambient light levels turn the photocell control center knob toward the sun symbol 5 Was sensor wired hot...

Страница 26: ...ounting 6 12ft allows maximum range 10 TechnicalTips Range Appears Limited WRONG RIGHT 40 20 50 6 12 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern mo...

Страница 27: ...roblem If your unit is out of warranty or the damage is unrelated to the original manufacture return your unit directly to us with a check for 30 00 made out to RAB Lighting We will repair or replace...

Страница 28: ...l Wire Nuts 3 Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answe...

Отзывы: